![LG 60PY2R Service Manual Download Page 21](http://html.mh-extra.com/html/lg/60py2r/60py2r_service-manual_1901856021.webp)
-21-
5. In case of occurring strange screen into specific mode
5-1. In case the OSD does not displayed
(1) Symptom
Ø
LED is green
Ø
The minute discharged continuously becomes
accomplished from module
(2) Check following
Is the LVDS cable
normal ?
Is the VSC Board
normal?
Is the LVDS cable
connected well?
Cable inserts well.
Yes
No
No
Yes
Does the FIL8532
IC(IC800) Operates ?
Replace FIL8532
IC(IC800).
No
Is the Ctrl Board of
Module normal?
Replace Ctrl B/D.
No
No
Yes
Replace VSC B/D
Replace the cable.
Yes