5.1.5. Adjustment method
5.1.5.1. Auto WB calibration
(1) Set TV in ADJ mode using P-ONLY key (or POWER ON
key)
(2) Place optical probe on the center of the display
- It need to check probe condition of zero calibration before
adjustment.
(3) Connect RS-232C Cable
(4) Select mode in ADJ Program and begin a adjustment.
(5) When WB adjustment is completed with OK message,
check adjustment status of pre-set mode (Cool, Medium,
Warm)
(6) Remove probe and RS-232C cable.
▪ W/B Adj. must begin as start command “wb 00 00” , and
finish as end command “wb 00 ff”, and Adj. offset if need
5.1.5.2. Manual adjustment
(1) Set TV in Adj. mode using POWER ON
(2) Zero Calibrate the probe of Color Analyzer, then place it on
the center of LCD module within 10cm of the surface..
(3) Press ADJ key → EZ adjust using adj. R/C → 8. White-
Balance then press the cursor to the right (KEY►).
(When KEY(►) is pressed 204 Gray(80IRE) internal
pattern will be displayed)
(4-a) Adjust modes (Cool) : Fix the G gain at least 172 and
change the others (R/B Gain).
▪ If R or B gain is over 255, G gain can be adjust below 172.
(4-b) Adjust two modes ( Medium / Warm) : Fix the one of
R/G/B gain to 192 (default data) and decrease the
others.
※
CASE : Cool mode
First adjust the coordinate far away from the target value(x,
y).B
(1) x, y >target
(2) x, y< target
(3) x >target , y< target
(4) x < target , y >target
- Every 4 case have to fit y value by adjusting B Gain and
then fit x value by adjusting R-Gain
- In this case, increasing/decreasing of B Gain and R Gain
can be adjusted.
► How to adjust
(1) Fix G gain at least 172 : Adjust R, B Gain ( In Case of
Mostly Blue Gain Saturation )
(2) When R or B Gain > 255, Release Fixed G Gain and
Readjust
※
CASE : Medium / Warm mode
First adjust the coordinate far away from the target value(x, y).
(1) x, y >target
i) Decrease the R, G.
(2) x, y< target
i) First decrease the B gain,
ii) Decrease the one of the others.
(3) x >target , y< target
i) First decrease B, so make y a little more than the target.
ii) Adjust x value by decreasing the R
(4) x < target , y >target
i) First decrease B, so make x a little more than the target.
ii) Adjust x value by decreasing the G
5.1.6. Reference (White Balance Adj. coordinate and
color temperature)
▪ Luminance: 204 Gray, 80IRE
** (normal line) LGD Cell
** Except Gumi winter season (Mar ~ Dec) & Global
▪ Standard color coordinate and temperature using
CA-210(CH-14) – by aging time
L14
Aging time
(Min)
Cool
Medium
Warm
X
Y
X
Y
X
Y
271
270
286
289
313
329
1
0-2
282 289 297
308
324
348
2
3-5
281 287 296
306
323
346
3
6-9
279 284 294
303
321
343
4
10-19
277 280 292
299
319
339
5
20-35
275 277 290
296
317
336
6
36-49
274 274 289
293
316
333
7
50-79
273 272 288
291
315
331
8
80-119
272 271 287
290
314
330
9
Over 120
271 270 286
289
313
329
** (Aging chamber) LGD Cell
▪ Standard color coordinate and temperature using
CA-210(CH-14) – by aging time
** (normal line) LGD Cell
** Gumi winter season (Jan ~ Feb) & Global, except Cinema
Screen models
▪ Standard color coordinate and temperature using
CA-210(CH-14) – by aging time
GP4
Aging time
(Min)
Cool
Medium
Warm
X
Y
X
Y
X
Y
271
270
286
289
313
329
1
0-2
286 295 301
314
328
354
2
3-5
284 290 299
309
326
349
3
6-9
282 287 297
306
324
346
4
10-19
279 283 294
302
321
342
5
20-35
276 278 291
297
318
337
6
36-49
274 275 289
294
316
334
7
50-79
273 272 288
291
315
331
8
80-119
272 271 287
290
314
330
9
Over 120
271 270 286
289
313
329
** INX, AUO, Sharp, CSOT Models (Cool Mode Spec :
13000K)
▪ Standard color coordinate and temperature using
CA-210(CH-14) – by aging time
cool
med
warm
x
y
x
y
x
y
spec
271
270
286
289
313
329
target
278
280
293
299
320
339