Checking order
1. Check IR cable condition between IR & Main board
2. Check the stand-by 3.5V on the terminal M1.
3. When checking the Pre-Amp when the power is in ON condition, it is normal when the Analog
Tester needle moves slowly, and defective when it does not move at all.
Standard Repair Process Detail Technical Manual
Remote controller operation checking method
D. Function error_ No response in remote controller,
key error
A15
Established
date
Revised
date
Error
symptom
Content
A15
JK6201
M7
GND
M4
+3.5V_ST
M3
NC
M1
IR
M6
EYE_SCL
M5
EYE_SDA
[SM5C Models]
Monitor Signage
JK6201
Copyright
ⓒ
2016 - 2017 LG Electronics Inc. All rights reserved.
Only training and service purposes.
Summary of Contents for 49SM5C