background image

- 4 -

LGE Internal Use Only

Copyright  © 

  LG Electronics. Inc. All rights reserved.

Only for training and service purposes

SERVICING PRECAUTIONS

CAUTION: Before servicing receivers covered by this service 

manual and its supplements and addenda, read and follow the 

SAFETY PRECAUTIONS

 on page 3 of this publication.

NOTE

: If unforeseen circumstances create conflict between the 

following servicing precautions and any of the safety precautions 

on page 3 of this publication, always follow the safety precau-

tions. Remember: Safety First.

General Servicing Precautions

1.  Always unplug the receiver AC power cord from the AC power 

source before;

a.  Removing or reinstalling any component, circuit board 

module or any other receiver assembly.

b.  Disconnecting or reconnecting any receiver electrical plug 

or other electrical connection.

c.  Connecting a test substitute in parallel with an electrolytic 

capacitor in the receiver.

CAUTION

: A wrong part substitution or incorrect polarity 

installation of electrolytic capacitors may result in an explo-

sion hazard.

2.  Test high voltage only by measuring it with an appropriate 

high voltage meter or other voltage measuring device (DVM, 

FETVOM, etc) equipped with a suitable high voltage probe.

Do not test high voltage by "drawing an arc".

3.  Do not spray chemicals on or near this receiver or any of its 

assemblies.

4.  Unless specified otherwise in this service manual, clean 

electrical contacts only by applying the following mixture to the 

contacts with a pipe cleaner, cotton-tipped stick or comparable 

non-abrasive applicator; 10 % (by volume) Acetone and 90 % 

(by volume) isopropyl alcohol (90 % - 99 % strength)

CAUTION

: This is a flammable mixture.

Unless specified otherwise in this service manual, lubrication 

of contacts in not required.

5.  Do not defeat any plug/socket B+ voltage interlocks with which 

receivers covered by this service manual might be equipped.

6.  Do not apply AC power to this instrument and/or any of its 

electrical assemblies unless all solid-state device heat sinks 

are correctly installed.

7.  Always connect the test receiver ground lead to the receiver 

chassis ground before connecting the test receiver positive 

lead.

Always remove the test receiver ground lead last.

8.  Use with this receiver only the test fixtures specified in this 

service manual.

CAUTION

: Do not connect the test fixture ground strap to any 

heat sink in this receiver.

Electrostatically Sensitive (ES) Devices

Some semiconductor (solid-state) devices can be damaged eas-

ily by static electricity. Such components commonly are called 

Electrostatically Sensitive (ES) Devices. Examples of typical ES 

devices are integrated circuits and some field-effect transistors 

and semiconductor “chip” components. The following techniques 

should be used to help reduce the incidence of component dam-

age caused by static by static electricity.

1.  Immediately before handling any semiconductor component or 

semiconductor-equipped assembly, drain off any electrostatic 

charge on your body by touching a known earth ground. Alter-

natively, obtain and wear a commercially available discharg-

ing wrist strap device, which should be removed to prevent 

potential shock reasons prior to applying power to the unit 

under test.

2.  After removing an electrical assembly equipped with ES 

devices, place the assembly on a conductive surface such as 

aluminum foil, to prevent electrostatic charge buildup or expo-

sure of the assembly.

3.  Use only a grounded-tip soldering iron to solder or unsolder 

ES devices.

4.  Use only an anti-static type solder removal device. Some sol-

der removal devices not classified as “anti-static” can generate 

electrical charges sufficient to damage ES devices.

5.  Do not use freon-propelled chemicals. These can generate 

electrical charges sufficient to damage ES devices.

6.  Do not remove a replacement ES device from its protective 

package until immediately before you are ready to install it. 

(Most replacement ES devices are packaged with leads elec-

trically shorted together by conductive foam, aluminum foil or 

comparable conductive material).

7.  Immediately before removing the protective material from the 

leads of a replacement ES device, touch the protective mate-

rial to the chassis or circuit assembly into which the device will 

be installed.

CAUTION

: Be sure no power is applied to the chassis or cir-

cuit, and observe all other safety precautions.

8.  Minimize bodily motions when handling unpackaged replace-

ment ES devices. (Otherwise harmless motion such as the 

brushing together of your clothes fabric or the lifting  of your 

foot from a carpeted floor can generate static electricity suf

-

ficient to damage an ES device.)

General Soldering Guidelines

1.  Use a grounded-tip, low-wattage soldering iron and appropri-

ate tip size and shape that will maintain tip temperature within 

the range or 500 °F to 600 °F.

2.  Use an appropriate gauge of RMA resin-core solder composed 

of 60 parts tin/40 parts lead.

3. Keep the soldering iron tip clean and well tinned.

4.  Thoroughly clean the surfaces to be soldered. Use a mall wire-

bristle (0.5 inch, or 1.25 cm) brush with a metal handle.

Do not use freon-propelled spray-on cleaners.

5.  Use the following unsoldering technique

a.  Allow the soldering iron tip to reach normal temperature. 

(500 °F to 600 °F)

b. Heat the component lead until the solder melts.

c.  Quickly draw the melted solder with an anti-static, suction-

type solder removal device or with solder braid.

CAUTION: Work quickly to avoid overheating the circuit 

board printed foil.

6.  Use the following soldering technique.

a.  Allow the soldering iron tip to reach a normal temperature 

(500 °F to 600 °F)

b.  First, hold the soldering iron tip and solder the strand 

against the component lead until the solder melts.

c.  Quickly move the soldering iron tip to the junction of the 

component lead and the printed circuit foil, and hold it there 

only until the solder flows onto and around both the compo

-

nent lead and the foil.

CAUTION

: Work quickly to avoid overheating the circuit 

board printed foil.

d.  Closely inspect the solder area and remove any excess or 

splashed solder with a small wire-bristle brush.

Summary of Contents for 49LX560H

Page 1: ... MFL69175104 1612 REV02 CAUTION BEFORE SERVICING THE CHASSIS READ THE SAFETY PRECAUTIONS IN THIS MANUAL LED TV SERVICE MANUAL Internal Use Only CHASSIS LA5CJ LA5CG MODEL 49LX570H 560H MODEL 49LX570H 560H U ...

Page 2: ...t LG Electronics Inc All rights reserved Only for training and service purposes CONTENTS CONTENTS 2 SAFETY PRECAUTIONS 3 SERVICING PRECAUTIONS 4 SPECIFICATION 6 USB DOWNLOAD 8 TROUBLE SHOOTING GUIDE 9 BLOCK DIAGRAM 17 EXPLODED VIEW 18 ...

Page 3: ...o be sure the set is safe to operate without damage of electrical shock Leakage Current Cold Check Antenna Cold Check With the instrument AC plug removed from AC source connect an electrical jumper across the two AC plug prongs Place the AC switch in the on position connect one lead of ohm meter to the AC plug prongs tied together and touch other ohm meter lead in turn to each exposed metallic par...

Page 4: ...ctrostatic charge on your body by touching a known earth ground Alter natively obtain and wear a commercially available discharg ing wrist strap device which should be removed to prevent potential shock reasons prior to applying power to the unit under test 2 After removing an electrical assembly equipped with ES devices place the assembly on a conductive surface such as aluminum foil to prevent e...

Page 5: ...he solder joints of the two original leads If they are not shiny reheat them and if necessary apply additional solder Fuse and Conventional Resistor Removal Replacement 1 Clip each fuse or resistor lead at top of the circuit board hollow stake 2 Securely crimp the leads of replacement component around notch at stake top 3 Solder the connections CAUTION Maintain original spacing between the replace...

Page 6: ...e of each parts are followed each drawing and specification by part number in accordance with BOM 5 The receiver must be operated for about 5 minutes prior to the adjustment 3 Test method 1 Performance LGE TV test method followed 2 Demanded other specification Safety CE IEC specification EMC CE IEC 4 Model General Specification No Item Specification Remarks 1 Receiving System ATSC NTSC M 64 QAM 25...

Page 7: ...45 000 60 000 74 250 HDTV 720P 4 1280 720 44 960 59 940 74 176 HDTV 720P 5 1920 1080 33 750 60 000 74 250 HDTV 1080I 6 1920 1080 33 720 59 940 74 176 HDTV 1080I 7 1920 1080 67 500 60 000 148 500 HDTV 1080P 8 1920 1080 67 4320 59 940 148 352 HDTV 1080P 9 1920 1080 27 000 24 000 74 250 HDTV 1080P 10 1920 1080 26 970 23 976 74 176 HDTV 1080P 11 1920 1080 33 750 30 000 74 250 HDTV 1080P 12 1920 1080 3...

Page 8: ... the message Copying files from memory 4 Updating is starting 5 Updating Completed the TV will restart automatically 6 If your TV is turned on check your updated version and Tool option explain the Tool option next stage If downloading version is more high than your TV have TV can lost all channel data In this case you have to channel recover if all channel data is cleared you didn t have a DTV AT...

Page 9: ...SET and UPDATE pin Check switch SW501 SW502 Y N Check X5000 Clock 32 768KHz Check X5000 application circuit or Replace X5000 Y N Check IC5002 IIC communication state Check IIC line orreplace IC5002 N Check IR input state of IC5002 57pin Check IR board N Y Re download PTC Micom Y Check LVDS Cable Check LCD Module Controlboard Y Replace Cable N Check P401 Voltage Level 13 2V L403 Check powerconnecto...

Page 10: ...Check tuner 5V powerL3000 YES NO Could you measure voltage of TU3001 IIC lines Are they all normal Check Mstar LVDS output NO You should check power line IIC lines YES You should replace TUNER NO Check IC5000 YES YES Check tuner 3 3V powerL3001 Replace L3001 NO Replace IC5000 Replace L3000 YES NO Check tuner 1 8V powerL3003 Replace IC3000 or IC3000 NO Check RF cable signal YES NO Replace Mstar IC1...

Page 11: ... Shooting guide Check RF Cable Check IIC Signal TU3001 3 4Pin Check IIC line and level shifter circuit Y N Check Tuner5V Power L3000 Check L3000 Y N Y Check X201 and application circuit Check IF Signal TU3001 10 11 Pin Check tuner application circuit or replace tuner N Y Replace X201 N Y Replace IC101 Replace IC5000 N Y Replace L3000 ...

Page 12: ...1 may have problem Replace this Jack Check the input of Mstar IC101 Measure waveform at C227 because it s more easy to check Can you see the normalwaveform Y This board hasbig problem because Main chip Mstar have some troubles After checking thoroughlyall path once again You should decide to replace Mstaror not Y Check input signal issupported format Y Check AC cable for damage or open conductor Y...

Page 13: ... JK802 may have problem Replace this Jack This board hasbig problem because Main chip Mstar have some troubles After checking thoroughlyall path once again You should decide to replace Mstar ornot Check input signal format Is it supported Y Check AC cable for damage For damage oropen conductor Y Y Check HDMI Switch IC Power Check L800 3 3V Not stand by mode Y Swap HDMI Switch IC is there same Prob...

Page 14: ...yall path once again You should decide to replace Mstaror not YES Check input signal format Is it supported YES Check AC cable for damage For damage oropen conductor YES Check RF Cable Signal Check Audio AMP output L5503 L5504 L5505 L5506 Y Check TU3001 Pin1 SIF Output Can you see the normalsignal Y Could you measure voltage of TU3001 IIC lines Are they all normal N You should check power line IIC...

Page 15: ...rm Replace P3300 JK5001 Y N Check AC cable for damage For damage oropen conductor Y Y Check the input of Mstar IC101 Measure waveform at C209 C211 because it s more easy to check Can you see the normalwaveform Y Check Audio AMP output L5503 L5504 L5505 L5506 Y Replace L5503 L5504 L5505 L5506 N This board hasbig problem because Main chip Mstar have some troubles After checking thoroughlyall path on...

Page 16: ...After checking thoroughlyall path once again You should decide to replace Mstar ornot Check the output of Mstar IC101 Measure waveform at R123 IC5600 Pin23 24 because it s more easy to check Can you see the normal signal YES NO This board hasbig problem because Main chip MStar have some troubles After checking thoroughlyall path once again You should decide to replace Mstaror not Check Audio AMP o...

Page 17: ... 17 LGE Internal Use Only Copyright LG Electronics Inc All rights reserved Only for training and service purposes BLOCK DIAGRAM ...

Page 18: ...EW Many electrical and mechanical parts in this chassis have special safety related characteristics These parts are identified by in the EXPLODED VIEW It is essential that these special safety parts should be replaced with the same components as recommended in this manual to prevent Shock Fire or other Hazards Do not modify the original design without permission of manufacturer IMPORTANT SAFETY NO...

Page 19: ......

Reviews: