LC12C Product Specification
6. Safety and Regulation
No Item
Min
Typ
Max
Unit
Remarks
1. Force Stability – Incline Plane Tip Test
10
12
Deg
2.
Clearances & Creepage,
: AC-AC
3.0 6
mm
3.
Clearances & Creepage,
: AC-GND
3.0 6
mm
4.
Clearances & Creepage
: Primary
↔
Secondary
6 7.5
mm
IEC60065
5.
Power
Consumption,
Max
42LW6500-CA
47LW6500-CA
55LW6500-CA
120
131
140
150
170
W
W
W
6.
Power
Consumption,
Stand by
All-inch
0.1
0.5
W
7.
Dielectric
Voltage
1.5
kV
8. Dielectric Voltage(for M/P)
1.8
kV
10
㏁
9.
Isolation
Resistance
4
∝
㏁
Energy Saving Spec
※
Maximum:40±15%
- Min / Medium / Screen off
has 10% difference each
other.
※
Power Consumption Stand by
- Power Indicator RED LED : Off
※
Dielectric Voltage (AC
↔
FG)
- 1.5kV/100mA/1min
- 1.8kV/100mA/1sec(M/P)
※
Dielectric Voltage(WITHOUT
FG)
External interface signal
line
↔
AC
- 3kV/100mA/1min
- 3.6kV/100mA/1sec
Energy Saving Spec
※
OFF : 100%
Minimum: 80±10%
Medium: 63±10%
Maximum: 43±10%
Screen Off: 29±10%
UL/CSA
0.5
mA
(rms)
10.
Leakage
Current
Etc.
0.35
V
Peak
11. Power cord Length
1.6
1.8
3.0
M
12. Sharp Edge
None
13.
Korea
Safety
K60065
Not
Applied
Summary of Contents for 47LW6500