4.3. LAN port Inspection (Ping Test)
4.3.1. Equipment setting
(1) Play the LAN Port Test PROGRAM.
(2) Input IP set up for an inspection to Test Program.
* IP Number : 12.12.2.2.
4.3.2. LAN PORT inspection (PING TEST)
(1) Play the LAN Port Test Program.
(2) connect each other LAN Port Jack.
(3) Play Test (F9) button and confirm OK Message.
(4) remove LAN CABLE
Step 1) Step 3) Check ‘OK’ Signal
4.4. EDID Download
4.4.1 Overview
▪ It is a VESA regulation. A PC or a MNT will display an
optimal resolution through information sharing without any
necessity of user input. It is a realization of “Plug and Play”.
4.4.2 Equipment
▪ Since embedded EDID data is used, EDID download JIG,
HDMI cable and D-sub cable are not need.
▪ Adjust remocon
4.4.3. EDID DATA
4.4.3.1. HD PCM (2D 8bit xvYCC : off) : 32LH570B-UC
(1) HDMI1 (6D , 08)
(2) HDMI2 (6D , F8)
4.4.3.2. HD AC3 (2D 8bit xvYCC : off) : 32LH570B-UC
(1) HDMI1 (6D , 96)