BATTERY LOW WARNING

•  Repeated beeping during an opening indicates that the battery is low and needs immediate replacement. LA GARD recommends the

replacement of batteries at least once annually.

•  Uses one (1) 9-Volt Alkaline Battery. LA GARD recommends the use of Duracell™ or Eveready™ Alkaline batteries.
•  

If battery is depleted and will not allow lock to open, follow instructions found on the User Instructions for your keypad. Lock
contains a non-volatile memory, even with batteries removed the lock will retain all programming.

WRONG TRY PENALTY

•  Entry of four (4) consecutive invalid codes starts a 5-minute delay period.

- LED flashes red at ten (10) second intervals.

•  At the end of the delay period, two more consecutive invalid codes will restart an additional 5-minute delay period.

During delay period a single keystroke will respond with three signals.

DUAL CODE OPERATION

(If feature is active.)

Must add second user to open lock. (See 

ADD USER

)  

•  

Second User cannot be disabled or removed.

If Time Delay is active, one valid code will start Delay period.

•  

Both codes required to open lock in Open period.

SET/CHANGE TIME  DELAY VALUES 

(Manager Only, with 

eKEY or e

KEY

II

)

Enter Manager code and hold in key until unit double signals twice and the LED stays on.

PRESS 9. Unit signals twice.

Enter Delay period value, from 00 to 99 minutes. For example five (5) minutes would be entered by pressing the 0 key and then the 5
key.

Enter Open period value, from 00 to 19 minutes. For example two (2) minutes would be entered by pressing the 0 key and then the 2
key. Unit will signal twice.

Note: Selecting 0000 minutes deactivates the Time Delay Feature.

Confirm all four values. Unit signals twice and feature is active.

NOTE: If Time Delay is active it may only be deactivated or delay value decreased in Open Period.

TIME DELAY OVERRIDE

(If feature is active.)

•  

Must add User 9. (See 

ADD USER

)

- User 9 cannot be disabled or deleted. If the User is disabled or deleted, this feature will no longer function.

•  

Entry of Override code during Delay period will open the lock.

SILENT SIGNAL ALARM 

(If feature is active AND optional Alarm Box is connected to an alarm system.)

•  

Enter last digit of code one number higher or one number lower.

Example:Code:

1-2-3-4-5-6
Duress: 1-2-3-4-5-5  or  1-2-3-4-5-7

•  

The lock will open without any indication that the duress signal has been sent.

RECEIVE AUDIT 

(Manager Only, with 

eKEY or e

KEY

II

)

This function requires Serial Interface (P/N 43087) and LGVIEW Software

Plug Interface into PC and open LGVIEW software on PC.

Enter Manager code and hold in key until unit double signals twice and the LED stays on.

Remove key and connect Interface to front of keypad and click safe icon button on the PC software to begin acquisition.

PRESS 7. Unit signals once and Audit will be sent.

Disconnect Interface Cable from PC and keypad.

CHANGING YOUR BATTERY

Open safe door.

Remove battery box cover by pulling the
front portion away from the safe door.

The connector is easily removed by
unsnapping it from the two terminals on
the top of the battery.

Never Pull on the Battery Leads

Connect a new 9-Volt Alkaline battery to
the battery clip.

Push the battery and the leads
completely up into the battery
compartment.

Replace the cover and test the unit
several times before closing the door

2788 Small Battery
Box or 2789 Small
Battery Alarm Box

4001 Large
Battery Box or
4002 Large
Battery/Alarm Box

CHANGING YOUR BATTERY

Open safe door.

Remove battery box cover by
pulling the front portion away
from the safe door.

Remove six “C” cell Alkaline
batteries.

Insert six new “C” cell batteries

Replace the cover and test the
unit several times before closing
the door

WARNING: The port for the 

eKEY

II

is a data port only. Connecting power to this port will damage the system.

LOCKS USING THE KEY FEATURE MUST BE ORDERED THAT WAY FROM THE FACTORY. PLEASE SEE PRICE LIST FOR

PART NUMBERS FOR LOCKS SET-UP FOR 

eKEY or e

KEY

II

USE

.

© copyright 2006

12-239v3

LA GARD INC - A Member of The Kaba Group

Summary of Contents for 4300

Page 1: ...last digit of code until unit double signals twice and the LED stays on 2 PRESS 2 Unit signals twice 3 Press User number 2 to 9 Unit signals once 4 User is temporarily disabled 5 If a mistake is made wait thirty 30 seconds and repeat steps 1 3 Valid Code Entry Double signal after valid six 6 digit code is entered Invalid Code Entry Triple signal and old code is still valid STANDARD FEATURES MANAGE...

Page 2: ...9 cannot be disabled or removed Entry of Override code during Delay period will open the lock SILENT SIGNAL ALARM If feature is active AND optional Alarm Box is connected to an alarm system Without eKEY or eKEYII Enter last digit of code one number higher or one number lower Example Code 1 2 3 4 5 6 Duress 1 2 3 4 5 5 or 1 2 3 4 5 7 The lock will open without any indication that the duress signal ...

Page 3: ...I ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN 1 Enter Manager code and hold in key until unit double signals twice and the LED stays on 2 PRESS 2 Unit signals twice 3 Press User number 2 to 9 Unit signals once 4 User is temporarily disabled 5 If a mistake is made wait thirty 30 seconds and repeat steps 1 3 Valid Code Entry Double signal after valid six 6 digit code is entered Invalid Code Ent...

Page 4: ... deleted If the User is disabled or deleted this feature will no longer function Entry of Override code during Delay period will open the lock SILENT SIGNAL ALARM If feature is active AND optional Alarm Box is connected to an alarm system Enter last digit of code one number higher or one number lower Example Code 1 2 3 4 5 6 Duress 1 2 3 4 5 5 or 1 2 3 4 5 7 The lock will open without any indicati...

Reviews: