9.3. Manual W/B Process
(using adjusts Remote control)
Please Adjust in AV 1 MODE, Turn off Energy Saving Mode.
(1) Enter “PICTURE RESET” on Picture Mode, then turn off
Fresh Contrast and Fresh colour in Advanced Control
(2) After enter Service Mode by pushing “ADJ” key,
(3) Enter White Pattern off of service mode, and change off ->
on.
(4) Enter “W/B ADJUST” by pushing “
G
” key at “3. W/B
ADJUST”.
(5) Adjust W/B DATA, for all CSM, choose ‘COPY ALL’
[
Gain Max Value is 192. So, Never make any Gain Value
over 192 and please fix one Value on 192, between R, G
and B.
9.4. Auto-control Interface and Directions
(1) Adjust in the place where the influx of light like floodlight
around is blocked.
(Illumination is less than 10ux).
(2) Measure and adjust after sticking the Color Analyzer (CA-
100+, CA210 ) to the side of the module.
(3) Aging time
After aging start, keep the Power on (no suspension of
power supply) and heat-run over 5 minutes
9.5. Auto Adjustment Map(RS232C)
10. Checking the EYE-Q Operation
(1) Press the EYE Key on the adjustment remote controller.
(2) Check the Sensor DATA (It must be under 10) and keep
the data longer than 1.5s
(3) Check ‘OK’
(Sensor DATA 0 ~ 4095, Power Saving Mode 0 ~ 12)
[
IF you press IN-STAP Button, change Green Eye-check OSD.
11. Set Information
(Serial No & Model name)
11.1. Check the Serial Number & Model Name
(1) Push the menu button in DTV mode.
(2) Check the Serial Number
Select the STATION ==> Diagnostics ==> To set
Summary of Contents for 42PQ1100