5
EXTERNAL CONTROL DEVICE SETUP
ENG
ENGLISH
Command reference list
Communication Parameters
y
Baud rate: 9600 bps (UART)
y
Data length: 8 bits
y
Parity : None
y
Stop bit: 1 bit
y
Communication code: ASCII code
y
Use a crossed (reverse) cable.
* Note : During USB operations such as DivX or EMF, all commands except Power(ka) and Key(mc) are
not executed and treated as NG.
COMMAND1 COMMAND2
DATA
(Hexadeci-
mal)
COMMAND1 COMMAND2
DATA
(Hexadeci-
mal)
01. Power off k
a
00
13. Balance
k
t
00 to 64
02. Aspect
Ratio
k
c
(See p.7)
14. Color
(Colour)
Temperature
x
u
00 to 64
03. Screen
Mute
k
d
(See p.7)
15. ISM
Method (Only
Plasma TV)
j
p
(See p.9)
04. Volume
Mute
k
e
00 to 01
16. Energy
Saving
j
q
00 to 05
05. Volume
Control
k
f
00 to 64
17. Tune
Command
m
a
(See p.9)
06. Contrast k
g
00 to 64
18. Channel
(Programme)
Add/Del(Skip)
m
b
00 to 01
07. Bright-
ness
k
h
00 to 64
19. Key
m
c
Key
Codes
08. Color/
Colour
k
i
00 to 64
20. Control
Back Light,
Control Panel
Light
m
g
00 to 64
09. Tint
k
j
00 to 64
21. Input se-
lect (Main)
x
b
(See p.11)
10. Sharp-
ness
k
k
00 to 32
22. 3D
(Only 3D
models)
x
t
(
See p.12
)
11. OSD
Select
k
l
00 to 01
23. Extended
3D (Only 3D
models)
x
v
(
See p.12
)
12. Remote
Control
Lock Mode
k
m
00 to 01
(Depending on model)