- 19 -
LGE Internal Use Only
Copyright LG Electronics. Inc. All right reserved.
Only for training and service purposes
3.2. Function Check
(1) Check display and sound
- Check Input and Signal items. (cf. work instructions)
1) TV
2) AV (CVBS)
3) COMPONENT (480i)
4) RGB (PC : 1024 x 768 @ 60hz)
5) HDMI
6) PC Audio In
* Display and sound check is executed by remote control.
* Caution :Not to push the INSTOP KEY after completion
if the function inspection.
4. Total Assembly line process
4.1. Adjustment Preparation
· W/B Equipment condition
CA210 : CH 9, Test signal : Inner pattern (85IRE)
· Above 5 minutes H/run in the inner pattern. (“power on” key
of adjust remote control)
4.1.1. Connecting picture of the measuring instrument
(On Automatic control)
Inside PATTERN is used when W/B is controlled. Connect to
auto controller or push Adjustment R/C POWER ON -> Enter
the mode of White-Balance, the pattern will come out
4.1.2. Auto-control interface and directions
1) Adjust in the place where the influx of light like floodlight
around is blocked. (illumination is less than 10ux).
2) Adhere closely the Color Analyzer (CA210) to the module
less than 10cm distance, keep it with the surface of the
Module and Color Analyzer’s Prove vertically.(80~100°).
3) Aging time
- After aging start, keep the power on (no suspension of
power supply) and heat-run over 15minutes.
- Using ‘no signal’ or ‘full white pattern’ or the others, check
the back light on.
4.1.3. Auto adjustment Map (RS-232C)
RS-232C COMMAND
[ CMD ID DATA ]
Wb 00 00 White Balance Start
Wb 00 ff White Balance End
** Caution **
Color Temperature : COOL, Medium, Warm.
One of R Gain/G Gain/ B Gain should be kept on 0xC0, and
adjust other two lower than C0. (when R/G/B Gain are all C0, it
is the FULL Dynamic Range of Module)
*Manual W/B process using adjusts Remote control.
•After enter Service Mode by pushing “ADJ” key,
•Enter White Balance by pushing “
G
” key at “7. White Balance”.
# After You finish all adjustments, Press “In-start” button and
compare Tool option and Area option value with its BOM, if
it is correctly same then unplug the AC cable. If it is not
same, then correct it same with BOM and unplug AC cable.
For correct it to the model’s module from factory JIG model.
# Push The “IN STOP KEY” after completing the function
inspection. And Mechanical Power Switch must be set
“ON”.
Cool 13,000k
ºK
X=0.269(±0.002)
All
Y=0.273(±0.002)
<Test Signal>
Medium 9,300k
ºK
X=0.285(±0.002)
Inner pattern
Y=0.293(±0.002)
(216gray,85IRE)
Warm
6,500k
ºK
X=0.313(±0.002)
Y=0.329(±0.002)
Cool 9,300k
ºK
X=0.285(±0.002)
Only 22LD350
Y=0.293(±0.002)
<Test Signal>
Medium 8,000k
ºK
X=0.295(±0.002)
Inner pattern
Y=0.305(±0.002)
(216gray,85IRE)
Warm
6,500k
ºK
X=0.313(±0.002)
Y=0.329(±0.002)
Full White Pattern
COLOR
ANALYZER
TYPE: CA-210
RS-232C Communication
CA-210
RS-232C COMMAND MIN
CENTER
MAX
[CMD ID DATA]
(DEFAULT)
Cool
Mid
Warm
Cool
Mid
Warm
R Gain
jg
Ja
jd
00
172
192
192
255
G Gain
jh
Jb
je
00
172
192
192
255
B Gain
ji
Jc
jf
00
192
192
172
255
R Cut
64
64
64
128
G Cut
64
64
64
128
B Cut
64
64
64
128
Summary of Contents for 42LV3500