- 15 -
2. No Power
(1) Symptom
Ø
Does’t minute discharge at module.
Ø
No front LED.
(2) Check follow
Power cord connected?
Plug in power cord.
Yes
No
Cable connecting the Line Filter
and Power Board connected?
Connect Cable.
Yes
No
Is Fuse(F101) on Power Board
good?
Replace Fuse.
Yes
No
Is the Power Board connected to
7P of VSC Board?
Connect Cable.
Yes
No
When ST-BY 5V does not operate,
replace Power Board.