29
ENGLISH
EXTERNAL CONTROL DEVICE SETUP
Communication Parameters
•
Baud rate: 9600 bps (UART)
•
Data length: 8 bits
•
Parity : None
•
Stop bit: 1 bit
•
Communication code: ASCII code
•
Use a null modem cable.
Command Reference List
COMMAND1 COMMAND2
DATA
(Hexadecimal)
COMMAND1 COMMAND2
DATA
(Hexadecimal)
01. Power
k
a
00 - 01
14. Balance
k
t
00 - 64
02. Input
Select
x
b
(See p. 31)
15. 3D (For
3D TV)
x
t
(See p. 32)
03. Aspect
Ratio
k
c
(See p. 31)
16. Color
Temperature x
u
00 - 64
04. Screen
Mute
k
d
00 - 01
17. Extended
3D (For 3D
TV)
x
v
(See p. 33)
05. Volume
Mute
k
e
00 - 01
18. Auto
Configuration j
u
(See p. 33)
06. Volume
Control
k
f
00 - 64
20. Channel
Add/Del
m
b
00 - 01
07. Contrast k
g
00 - 64
21. Key
m
c
(See p. 34)
08.
Brightness
k
h
00 - 64
22. Backlight m
g
00 - 64
09. Color
k
i
00 - 64
23. Equalize
j
v
(See p. 34)
10. Tint
k
j
00 - 64
11.
Sharpness
k
k
00 - 32
12. OSD
Select
k
l
00 - 01
13. Remote
Control
Lock Mode
k
m
00 - 01
COMMAND1 COMMAND2
DATA00
(Hexadecimal)
DATA01
(Hexadecimal)
DATA02
(Hexadecimal)
DATA03
(Hexadecimal)
DATA04
(Hexadecimal)
DATA05
(Hexadecimal)
19.
Channel
Tuning
m
a
physical
program
high
major
program
low
major low minor high minor low attribute