3. Main PCB check process
*
APC - After Manual-Insert, executing APC
* Boot file Download
1. Execute ISP program “Mstar ISP Utility” and then click “Config” tab.
2. Set as below, and then click “Auto Detect” and check “OK” message
If “Error” is displayed, Check connection between computer, jig, and set.
3. Click “Read” tab, and then load download file (XXXX.bin) by clicking “Read”
4. Click “Connect” tab. If “Can’t ” is displayed, Check connection between computer, jig, and set.
5. Click “Auto” tab and set as below.
6. Click “Run”.
7. After downloading, check “OK” message.
(1)
filexxx.bin
(2)
(3)
Please Check the Speed :
To use speed between
from 200KHz to 400KHz
filexxx.bin
(4)
(7) ……….OK
(5)
(6)