LCD DV
32LH30
32
Spring 2009
Power Supply Connector SK100 and SK101 Voltage and Diode Check
Power Supply Connector SK100 and SK101 Voltage and Diode Check
Diode Check taken with meter in Diode Mode with all Connectors Removed
AC Voltage Readings Across Pins 1 and 2
for STBY and RUN.
OL
N
2
OL
120Vac
L
1
Diode Check
Run
STBY
Label
Pin
AC Voltage Readings for either pin 1 or pin
2 in STBY and RUN with one lead on
Neutral of SK101.
OL
n/a
2
OL
120Vac
n/a
1
Diode Check
Run
STBY
Label
Pin
SK100 "SMPS" to AC IN
SK101 "SMPS" to MASTER POWER SWITCH
SK101
SK100
Bottom Right of SMPS
Live
Neutral
With the Master Power Switch Closed (On) AC flows.
When Open (Off) AC open and does not flow.