4. Total Assembly line process
4.1. Adjustment Preparation
■ W/B Equipment condition
CA210 : CH14, Test signal : Inner pattern (80IRE) – in case of
LED back light
■ Above 5 minutes H/run in the inner pattern. (“power on” key of
adjust remote control)
► The spec of color temperature and coordinate
Model
Mode
Color Temp
Color coordinate
Remark
All
Cool (C50)
13,000k
x = 0.271 (±0.002)
y = 0.270 (±0.002)
※
Test signal
- Inner pattern for W/B adjust
- External white pattern
(80IRE, 204gray)
Medium (0)
9,300k
x = 0.286 (±0.002)
y = 0.289 (±0.002)
Warm (W50)
6,500k
x = 0.313 (±0.002)
y = 0.329 (±0.002)
► CA210 : CH 14, Test signal : Inner pattern (80IRE)
- Standard color coordinate and temperature using CA-1000 (by
H/R time)
▪ L14 LGD, INX Module
March to December & Global
Normal line (LB5500, LB5600)
H/R Time(Min)
Cool
Medium
Warm
x
y
x
x
y
x
271
270
285
293
313
329
1
0-2
281
285
295
308
323
344
2
3-5
280
284
294
307
322
343
3
6-9
279
282
293
305
321
341
4
10-19
277
279
291
302
319
338
5
20-35
275
275
289
298
317
334
6
36-49
273
273
287
296
315
332
7
50-79
272
272
286
295
314
331
8
80-119
271
270
285
293
313
329
9
Over 120
271
270
285
293
313
329
▪ Aging chamber line (LB5500, LB5600)
H/R Time(Min)
Cool
Medium
Warm
x
y
x
x
y
x
271
270
285
293
313
329
1
0-5
280
285
294
308
319
340
2
6-10
276
280
290
303
315
335
3
11-20
272
275
286
298
311
330
4
21-30
269
272
283
295
308
327
5
31-40
267
268
281
291
306
323
6
41-50
266
265
280
288
305
320
7
51-80
265
263
279
286
304
318
8
81-119
264
261
278
284
303
316
9
Over 120
264
260
278
283
303
315
※
Connecting picture of the measuring instrument
(On Automatic control)
Inside PATTERN is used when W/B is controlled. Connect to
auto controller or push Adjustment R/C POWER-ON -> Enter
the mode of White-Balance, the pattern will come out.
●
Auto-control interface and directions
(1) Adjust in the place where the influx of light like floodlight
around is blocked. (Illumination is less than 10ux).
(2) Adhere closely the Color Analyzer ( CA210 ) to the module
less than 10cm distance, keep it with the surface of the
Module and Color Analyzer’s Prove vertically.(80~100°).
(3) Aging time
- After aging start, keep the power on (no suspension of
power supply) and heat-run over 5 minutes.
- Using ‘no signal’ or ‘full white pattern’ or the others, check
the back light on.
● Auto adjustment Map(RS-232C)
RS-232C COMMAND
[ CMD ID DATA ]
Wb 00 00 White Balance Start
Wb 00 ff White Balance End
RS-232C COMMAND
[CMD ID DATA]
MIN
CENTER
(DEFAULT)
MAX
Cool
Mid
Warm
Cool
Mid
Warm
R Gain
jg
Ja
jd
00
172
192
192
192
G Gain
jh
Jb
je
00
172
192
192
192
B Gain
ji
Jc
jf
00
192
192
172
192
R Cut
64
64
64
128
G Cut
64
64
64
128
B Cut
64
64
64
128