- 11 -
Select the MICOM Model.(M16C/6H Group --> M306H3FC)
[
After setting, you need not set, again.
4-2. JIG Connection
Connection to the Micom Port on the TV Board.
(Spot of the red line(an arrow)is connected to the port 1.)
4-3. Program Download
5. EDID Data Input
5-1. Required Test Equipment
(1) PC, Jig for adjusting DDC. (256 bytes write)
(2) S/W for writing DDC(EDID data write & read)
5-2. Setting of Device
5-3. Adjustment
(1) Set devices as above and turn on the PC and JIG.
(2) Open S/W for writing DDC (EDID data write & read).
(3) Enter the Model-->Open in the Menu and then select EDID
DATA.
(4) Click the Digital and cancel the ANALOG.
Then connect to turn on the yellow light at the board &
connection.
(5) Click the Write Data & Verify and then download the EDID
DATA.
ADJUSTMENT INSTRUCTIONS
<MICOM JIG>
Connection
the Computer
Program Click
3. When the program is clicked, appear the window as below
PC
JIG
TV
SET
1. In performing the Download program, if it rightly connects
to the board, it is appeared as upper red box.
And it is appeared as lower dialog box.
2. Click the OPEN to select the download program.
So appear the dialog box.