C
HAPTER
4
| Making Network Connections
Cable Labeling and Connection Records
– 42 –
ES-3026/3026P
100 M
BPS
F
AST
E
THERNET
C
OLLISION
D
OMAIN
10 M
BPS
E
THERNET
C
OLLISION
D
OMAIN
C
ABLE
L
ABELING
AND
C
ONNECTION
R
ECORDS
When planning a network installation, it is essential to label the opposing
ends of cables and to record where each cable is connected. Doing so will
enable you to easily locate inter-connected devices, isolate faults and
change your topology without need for unnecessary time consumption.
To best manage the physical implementations of your network, follow these
guidelines:
◆
Clearly label the opposing ends of each cable.
◆
Using your building’s floor plans, draw a map of the location of all
network-connected equipment. For each piece of equipment, identify
the devices to which it is connected.
◆
Note the length of each cable and the maximum cable length supported
by the switch ports.
◆
For ease of understanding, use a location-based key when assigning
prefixes to your cable labeling.
Table 8: Maximum 1000BASE-LH Gigabit Ethernet Cable Length
Fiber Size
Fiber Bandwidth
Maximum Cable Length
Connector
9/125 micron single-
mode fiber
N/A
2 m - 70 km
(7 ft - 43.5 miles)
LC
Table 9: Maximum 100BASE-FX Cable Length
Type
Fiber Type
Max. Cable Length
Connector
100BASE-FX
9/125 micron single-mode
fiber
2 m - 20 km
(7 ft - 12.43 miles)
LC
62.5/125 or 50/125
multimode fiber
up to 2 km (1.24 miles)
LC
Table 10: Maximum Fast Ethernet Cable Length
Type
Cable Type
Max. Cable Length
Connector
100BASE-TX
Category 5 or better 100-ohm
UTP or STP
100 m (328 ft)
RJ-45
Table 11: Maximum Ethernet Cable Length
Type
Cable Type
Max. Cable Length
Connector
10BASE-T
Category 3 or better 100-ohm UTP
100 m (328 ft)
RJ-45