User Manual
PAGE :
REG. DATE : 2020.07.30
REV. DATE : 2020.07.30
REV.NO : 1.0
©2015 LGIT. All rights reserved.
4 / 8
MODEL :
ETWADYEC01(LGIT)
WL1NB6V2(LGE)
4. Storage Conditions
5. Operating Conditions
Parameter
Min
Max
Unit
Storage Temperature
-10
+80
℃
Storage Humidity (@ 40
℃
)
-
90
%
Caution
: The specifications above the Table define levels at which permanent damage
to the device can occur. Function operation is not guaranteed under these conditions.
Operating at absolute maximum conditions for extend periods can adversely affect the
long-term reliability of the device.
• Other conditions
1) Do not use or store modules in the corrosive atmosphere, especially where chloride
gas, sulfide gas, acid, alkali, salt or the like are contained.
Also, avoid exposure to moisture.
2) Store the modules where the temperature
and relative humidity do not exceed 5 to 40
℃
and 20 to 60%.
Parameter
Min
Typ
Max
Unit
Ambient Temperature
0
-
+60
℃
Operating Humidity (40
℃
)
-
-
85
%
Supply Voltage
3.15
3.3
3.45
V
dc