iPECS-MG Hardware Description and Installation Manual
Issue 1.1
DECT INSTALLATION
August, 2010
58
Figure 5.4.5.4-1 WTIB Ferrite Core and Base Station
5.4.5.5 WTIB Wiring
Each Base Station port on the WTIB is terminated to an RJ45 connector wired as shown in the pin-
out chart below. Separate wiring is required for the TX and RX pairs. Power is delivered from the
WTIB to the Base Station over the simplex circuit formed by the TX and RX pairs.
Referring to the pin-out charts and Figure 5.4.5.5-1 below and Figure 5.4.5.4-1,
plug RJ45 terminated cable with the Ferrite core into the appropriate WTIB connector.
wire each WTIB RJ45 TX and RX pair to the System DECT Base Station termination point using
CAT3 or better wiring. The maximum total wire length is 600M/1.9Kft of 22 AWG.
tag or number wiring for maintenance.
NOTE:
1. A shorter cable length between the WTIB and System DECT Base Stations will decrease the possibility of
data degradation.
2. For best operation,
All
wiring from the WTIB to the Base Stations should use unshielded twisted pair wiring
(at least Cat 3) of a consistent gauge and kept at the shortest length possible.