| Troubleshooting
Stack Troubleshooting
– 74 –
ES-4550G / ES-4526G
If any changes occur to a slave unit, such as unit failure or insertion of a new
unit, operation of the other units in the stack are not affected. On the other
hand, if the master unit fails, the unit with the lowest MAC address is elected as
the new master. The stack reboots, discovers the new stack topology, assigns
identifiers to each unit, and checks the software images on each unit. This
process make take up to two minutes.
If you do not connect a wrap-around cable from the bottom unit back up to the
top unit in the stack, the failure of a single unit will cause the stack to break into
two separate stacks. In this case, a master unit will be elected for both of the
stacks. However, backup information inherited from the previous master unit will
cause the same IP address to be used by both master units in the two stacks.
You must therefore manually reconfigure the IP address of the management
interface on one of the master units.