viii
France and Peru only
This unit cannot be powered from IT. supplies. If your supplies are of
IT type, this unit must be powered by 230 V (2P+T) via an isolation
transformer ratio 1:1, with the secondary connection point labelled
Neutral, connected directly to earth (ground). †Impédance à la terre
Power Cord Set
U.S.A. and
Canada
The cord set must be UL-approved and CSA
certified.
The minimum specifications for the flexible
cord are: - No. 18 AWG - not longer than 2
meters, or 16 AWG. - Type SV or SJ -
3-conductor
The cord set must have a rated current
capacity of at least 10A.
The attachment plug must be an
earth-grounding type with NEMA 5-15P (15 A,
125 V) or NEMA 6-15P (15 A, 250 V)
configuration.
Denmark
The supply plug must comply with Section
107-2-D1, Standard DK2-1a or DK2-5a.
Switzerland
The supply plug must comply with SEV/ASE
1011.
U.K.
The supply plug must comply with BS1363
(3-pin 13 A) and be fit-ted with a 5 A fuse
which complies with BS1362.
The mains cord must be <HAR> or <BASEC>
marked and be of type HO3VVF3GO.75
(minimum).
Europe
The supply plug must comply with CEE7/7
(.SCHUKO.).
The mains cord must be <HAR> or <BASEC>
marked and be of type HO3VVF3GO.75
(minimum).
IEC-320 receptacle.