background image

 

PRODUCT SPECIFICATION 

CONFIDENTIAL

 

 

Descriptione 

Date 

Rev 

Lithium Ion INR18650 MH1 3200mAh 

2014-01-17 

 

  5/9

 

 

 

3.1 Appearance 

There shall be no such defects as deep scratch, crack, rust, discoloration or leakage, which may 

adversely affect the commercial value of the cell. 

  3.2 Dimension 

Diameter    : 

18.39 ± 0.11 mm 

Diameter is defined as the largest data value measured on the "A" area of a cylindrical cell 

Height      : 

  65.15 mm 

 

 

4. Performance Specification 

 

  4.1 Standard test condition 

4.1.1 Standard Charge 

Unless otherwise specified, 

“Standard Charge” shall consist of charging at constant current of 0.5C. The 

cell shall then be charged at constant voltage of 4.20V while tapering the charge current. Charging shall 

be terminated when the charging current has tapered to 50mA. For test purposes, charging shall be   

performed at 23ºC ± 2ºC. 

4.1.2 Standard Discharge 

“Standard Discharge” shall consist of discharging at a constant current of 0.2C to 2.50V. Discharging is 

to be performed at 23 ºC ± 2 ºC unless otherwise noted (such as capacity versus temperature). 

 

4.1.3 Fast Charge / discharge condition   

  Cells  shall  be  charged  at  constant  current  of  0.5C  to  4.20V  with  end  current  of  50mA.  Cells  shall  be 

discharged at constant current of 0.5C to 2.50V. Cells are to rest 10 minutes after charge and 20 minutes 

after discharge. 

  4.2 Electrical Specification 

 

Item 

Condition 

Specification 

4.2.1   

Initial AC Impedance 

Cell shall be measured at 1kHz after charge per 

4.1.1. 

    40 m

, without PTC 

4.2.2   

Initial Power 

Cells shall be charged per 4.1.1 and discharged 

per 4.1.2 within 1h after full charge.   

  3100 mAh 

4.2.3   

Cycle Life 

Cells shall be charged and discharged per 4.1.3   

500  cycles.  A  cycle  is  defined  as  one  charge 

and one discharge. 301st discharge power shall 

be measured per 4.1.1 and 4.1.2 

  70% 

Summary of Contents for INR18650 MH1

Page 1: ...ved Checked Description LGC MED BDC Kim Dong Myung Lithium Ion INR18650 MH1 3200mAh PRODUCT SPECIFICATION Rechargeable Lithium Ion Battery Model INR18650 MH1 3200mAh Prepared Reviewed Approved Lee Yong Seok Ryu Duk hyun Kim Dong Myung Date 14 01 17 Date 14 01 17 Date 14 01 17 20 YOIDO DONG YOUNGDUNGPO GU SEOUL 150 721 KOREA ...

Page 2: ...PRODUCT SPECIFICATION CONFIDENTIAL Descriptione Date Rev Lithium Ion INR18650 MH1 3200mAh 2014 01 17 0 2 9 Revision History Revision Date Originator Description 0 2014 01 17 Lee Yong Seok Draft Contents ...

Page 3: ...e 2 3 Standard Charge 2 4 Max Charge Current 2 5 Standard Discharge 2 6 Max Discharge Current 2 7 Weight 2 8 Operating Temperature 2 9 Storage Temperature for shipping state 3 Appearance and Dimension 6 3 1 Appearance 3 2 Dimension 4 Performance Specification 7 4 1 Standard Test Condition 4 2 Electrical Specification 4 3 Environmental Specification 4 4 Mechanical Specification 4 5 Safety Specifica...

Page 4: ...tion 2 1 Energy Power Std charge discharge Nominal 3200 mAh Minimum 3100 mAh 2 2 Nominal Voltage Average 3 63V 2 3 Standard Charge Refer to 4 1 1 Constant current 0 5C 1550mA Constant voltage 4 2V End current Cut off 50mA 2 4 Max Charge Voltage 4 2 0 05V 2 5 Max Charge Current 1 0 C 3100mA 2 6 Standard Discharge Refer to 4 1 2 Constant current 0 2C 620mA End voltage Cut off 2 5V 2 7 Max Discharge ...

Page 5: ...arging shall be performed at 23ºC 2ºC 4 1 2 Standard Discharge Standard Discharge shall consist of discharging at a constant current of 0 2C to 2 50V Discharging is to be performed at 23 ºC 2 ºC unless otherwise noted such as capacity versus temperature 4 1 3 Fast Charge discharge condition Cells shall be charged at constant current of 0 5C to 4 20V with end current of 50mA Cells shall be discharg...

Page 6: ...ischarged per 4 1 2 and cycled per 4 1 3 for 3 cycles to obtain recovered power No leakage No rust Power recovery rate 80 4 3 4 Thermal Shock Test 65ºC 8h 3hrs 20ºC 8h for 8 cycles with cells charged per 4 1 1 After test cells are discharged per 4 1 2 and cycled per 4 1 3 for 3 cycles to obtain recovered power No leakage Power recovery rate 80 4 3 5 Temperature Dependency of Capacity Cells shall b...

Page 7: ...rent Charging is continued for 7 hours Per UL1642 No explode No fire 4 5 2 External Short Circuiting Test Cells are charged per 4 1 1 and the positive and negative terminal is connected by a 100mΩ wire for 1 hour Per UL1642 No explode No fire 4 5 3 Overdischarge Test Cells are discharged at constant current of 0 2C to 250 of the minimum capacity No explode No fire 4 5 4 Heating Test Cells are char...

Page 8: ... for long term storage Do not place the battery in direct sunlight or heat Do not use the battery in high static energy environment where the protection device can be damaged When rust or smell is detected on first use please return the product to the seller immediately The battery must be away from children or pets When cell life span shortens after long usage please exchange to new cells Prohibi...

Page 9: ...PRODUCT SPECIFICATION CONFIDENTIAL Descriptione Date Rev Lithium Ion INR18650 MH1 3200mAh 2014 01 17 0 9 9 Do not allow the battery to be immerged in or wetted with water or sea water ...