ASSEMBLY INSTRUCTIONS
Hardware Used
AA
x 3
Mounting
Screw
AA
5. Coat the top 1 in. of the post with clear silicone
caulk (not supplied) and position the post fitter
on the fixture body (D) onto the post. Be sure to
seat it completely, aligning the holes in the fitter
with the 1/16 in. pilot holes drilled into the post.
Secure the fixture to post with 3 mounting screws (AA).
5
4. Attach ground fixture wire to the ground wire
from the post (usually GREEN or BARE). Connect
the neutral WHITE or RIBBED side fixture wire to
the neutral usually WHITE wire from the post.
Connect the hot BLACK or SMOOTH side fixture
wire to the hot usually BLACK wire from the
post. Fasten wires together with a wire
connector (BB) and tightly wrap wire connector
(BB) with electrical tape (not included).
4
White Wire
From Post
Black Wire
From Post
Bare, or Green
Ground Wire
Bare, or Green
Fixture Ground Wire
From Post
White or
Ribbed Side
From Fixture
From Fixture
Black or
Smooth Side
BB
Hardware Used
BB
x 3
Wire
Connector
Post
Mounting
Hole
Post Fitter
D