8 Troubleshooting
Fault
Pump does not start up
Cause
Wrong or loose connection at motor terminal
Remedy
Check the connections
Cause
Pump is blocked
Remedy
Contact us
Cause
Belt is broken
Remedy
Contact us
Cause
Motor is defective
Remedy
Contact us
Cause
Wrong supply voltage
Remedy
Check the mains power or inverter
Fault
Motor protective switch triggers
Cause
Pump is blocked
Remedy
Contact us
Cause
Motor is defective
Remedy
Contact us
Cause
Wrong setting of protective switch
Remedy
Cause
Wrong direction of rotation
Remedy
Check and change the direction of rotation if applicable
Cause
Wrong supply voltage
Remedy
Check the mains power
Cause
Exhaust line is clogged
Remedy
Clean the exhaust line
Fault
Pump does not reach vacuum performance
Cause
Inlet filter is clogged
Remedy
Clean the inlet filter (if in use)
Cause
Gas leak at the pump inlet
Remedy
Check O-ring at inlet port or connections of accessories
Cause
Wrong rotational speed
Remedy
Check the mains frequency or inverter
300766038_002_C3 - 09/2021 - © Leybold