5.2.13
Serial Interface
The CMOVE 1250 can be operated via the RS232 and RS485 interfaces; see chapter
«5.5 Operation Via Serial Interface».
Which interface should be used?
RS232:
For line lengths <25 m and little interference
(control and supply lines)
«PRI-Status: On» "n" is transmitted
«PRI-Status: Off» "n" is not transmitted
RS485:
For line lengths <100 m and/or much interference
(control and supply lines)
«PRI-Status: On» "n" is transmitted
«PRI-Status: Off» "n" is not transmitted
Detailed information regarding PR status (for both interfaces) see chapter
«5.5.6 Actual Value.
The «Configuration» display shows the current
settings of the operating mode, valve type, pressure
sensor, and nominal value (setpoint) with source
(I = internal, E = external). Press
to get to the «Inputs/Outputs» display.
The «Inputs/Outputs» display shows the following
menu:
«DI»
Digital inputs
«DO»
Digital outputs
«AI/AO»
Analog inputs/outputs
«SERIAL»
Serial interfaces
to get to the «Interface» display.
to return to the «Configuration» display.
I/O
VALVE SENSOR I/O GEN.
Mode :
Pressure
Valve :
MOVE1250STD
Sensor :
CTR1000T
Nom. I : 1.33E+01 mbar
Configuration
SERIAL
DI DO AI/AO SERIAL
Inputs/Outputs