background image

______________________________________________________

Operation and Care

 

 

AUTO  OPERATION (Auto-Fill™ Models Optional on Versas Spa):  

 

1.1  Use faucet knob to adjust optimal water temperature at “H” (Left) or “C” (Right) directory. 
1.2  Pull out and tilt down faucet knob to shut off water any time during the automatic or manual 

operational cycle. 

 

                   

 

   

 
 

 

Water will automatically turn-off when optimal water level is detected by 2 sensors.  

  Auto-Fill™ option can be simply reset to normal manual mode as a contingent system when 

automatic operation becomes unavailable. Please call our Customer care for  instructions. 
 

 

If you notice the water stops before reaching water sensors. This might cause by the power unstable 
at that moment. To continue filling, turn the Auto-Fill knob clockwise again.

  

 
 
 
 

        

Auto-Fill™ / Jet Switch

 

(

Dual-functional momentary switch located on the right side of the front panel

)  

 

1. 

To turn water on: 

Turn knob clockwise and release. Water will fill up to reach the   

       

sensor level and activate the whirlpool jets  

2. 

To turn water off: 

Turn knob clockwise and release to turn off water. The switch can be activated 

to turn on or turn off water any time during the Auto-Fill™ cycle,  
 

NOTE: 

 Activate this Auto-Fill/Jet Knob: 

1.  When water is running, system will resume with turn off water. 
2.  When Whirlpool Jet is running, system  will resume with turn off Jet 
3.  When water is full and Jet is off, system will resume with fill up water for 3sec and Jet turns on. 
4.  When water level is low, system will resume with fill up water prior activating whirlpool jet 

 
Drain Switch: 

 

(Dual Action Electro-mechanical Switch located on the left side of the front panel) 
When activating the switch, it will raise the drain-stopper and power up the drain pump (if exist) at the 
same time. 

 

1. 

To drain water: 

Turn the drain knob clockwise.  Drain pump is activated.  

2. 

To turn off the drain pump: 

Turn the drain knob counterclockwise. 

 

CAUTION: Reset the Drain knob to vertical position to close the drain stopper prior fill up water

 

Important

!

  

Must scrub and clean water sensors frequently to ensure that water stops right at sensor 

level. If necessary, clean using sponge buffer

.

 

Warning

  

Water control knob must be used to shut off water supply to basin when spa  

                 chair is left unattended and overnight  

 

13 

Summary of Contents for VERSAS

Page 1: ...sprint of this advertisement Lexor s footspa specification and prices may change without prior notice Pedicure Spas are intended for professional used only always follow your State Board s sanitation...

Page 2: ...Recognition as published in the appropriate UL Directory As a supplementary means of identifying products that have been produced under UL s Component Recognition Program UL s Recognized Component Mar...

Page 3: ...n Flow Pattern for Gravity Drain 8 Plumbing Flow Pattern for Power Drain under ground 9 Hot and Cold Water Supply Lines 10 SPA SPECIFICATION Electrical and Pedicure Spa Component Specifications 11 OPE...

Page 4: ...THIS UNIT UNLESS THEY ARE CLOSELY SUPPERVISED AT ALL TIME LIRE LES INSTRUCTION DU FABRICANT AVANT DE METTRE EN MARCHE UTILISER SEULEMENT A L INTERIEUR COUPER LE COURANT AVANT DE PROCEDRE AU DEPANNAGE...

Page 5: ...st Cushion 4 Massage Remote Control 5 Manicure Tray Optional 6 Tub Bowl 7 Footrest 8 Sani Drain System with Discharge On Off Knob 9 Hot Cold Water Mixer Valve 10 Dual Function Auto Fill Jet On Off Kno...

Page 6: ...SPA to SPA RECOMMENDED CLEARANCE TOP CHAIR REVISION 1 FOLD AND UNFOLD BACK REST MASSAGE 1 To set backrest up Lift up the backrest until a Click is heard Make sure the lever is locked 2 before operati...

Page 7: ...up Plug arm rest into seat frame until Click is heard Raise Tray to horizontal level and push in Step 2 Pull up this Lock Ring to remove Arm Rest Step 3 Lift Up this Latch to unlock the locking device...

Page 8: ...mended since debris from broken rubber seal might clog water mixer Failure to do so may void your Warranty 3 Backflow preventer Due to differences in construction lay out of your Salon and City s plum...

Page 9: ...__Installation POWER DRAIN Connect Drain System with Drain Pump Using schedule 40 PVC Power Drain Connect drain to meet local plumbing codes Flexible connection to the drain should be removable for ea...

Page 10: ...lease follow below Determine if your spa chair is used for a new construction of a salon or a replacement spa chair 1 New construction Make sure to remove any and all debris and or dust from current h...

Page 11: ...ctro mechanically operated reclining massaging and sliding seat with hand held control One 1 pipe less whirlpool jet Pipe free technology Power drain or Gravity drain Extendable water spray positioned...

Page 12: ...level decreases simply add more water Whirlpool Starting Turn the Jet Knob located on the right side of the front panel to clockwise to turn on Turn counterclockwise to shut off Warning Do NOT turn O...

Page 13: ...knob clockwise and release to turn off water The switch can be activated to turn on or turn off water any time during the Auto Fill cycle NOTE Activate this Auto Fill Jet Knob 1 When water is running...

Page 14: ...RSION Turn Counterclockwise to remove Cap Cover Turn Clockwise to Close Cap Cover AUTOFILL SYSTEM USING PLASTIC LINER Option on QSpa Position the Trench Mark on impeller housing to 12 O clock Logo mus...

Page 15: ...e Press again to turn off massage Auto and Manual mode will run for duration of 20min 2 Press any button Rolling Spot Kneading Tapping and Combine to enter Manual mode 3 Press Rolling Spot to stop rol...

Page 16: ...shall be drained and all debris shall be removed from the spa basin 2 The spa basin must be cleaned with soap or detergent and water 3 The spa basin must be disinfected with an EPA registered disinfe...

Page 17: ...ot require a technician onsite Phone support on Thanksgiving Christmas New Years Chinese New Year s and Independence Day are not available Shipping Damages Shipping damages must be claimed within 48 h...

Page 18: ...INC 14800 GOLDENWEST ST WESTMINSTER CA 92683 USA CUSTOMER CARE TEL 1 800 559 3630 FAX 1 714 622 1740 www lexor com 2012 All Rights reserved Design and Specifications are subject to change without noti...

Reviews: