Diagnostic information
2-163
7002-xxx
Print quality—banding
Service tip: Banding is difficult to detect, except on a page with a uniform gray or a large amount of graphics
printed on the page. Banding is primarily due to a variation in the speed of the paper as it feeds through the
printer, especially in the development and transfer process. Inspect the alignment assembly, main drive
assembly, and all other paper feed components for signs of wear, dirt, binds, or damage, especially the drive
gears. Banding appears as light or dark horizontal lines on a uniformly gray page.
Banding can also be caused by a defective charge roll brush contact or HVPS. Check the charge roll contact for
damage and for proper connection to the HVPS and print cartridge.
Print quality—black bands on outer edges of the page
This print quality problem appears as vertical black bands on one or both sides of the copy and can be wide,
narrow, light, or dark.
Print quality—residual image
Service tip: Install a new print cartridge if available before doing this service check. Residual image can be
caused by the photoconductor, cleaning blade, and other parts inside the print cartridge.
FRU
Action
1
Charge roll counterbalance
springs
If the problem is just on one side of the page, check the charge roll
counterbalance spring on that side. You can check to see if enough
force is being applied to the charge roll by applying slight downward
pressure with your finger to the charge roll link arm that the spring is
attached to while you run a print test sample. See if the problem
changes or goes away. If this fixes or changes the problem, then
check the springs and charge roll link arm assemblies for binds or
defective parts. Replace as necessary.
2
Charge roll assembly
Charge roll link arm
Check the charge roll for toner buildup or other contamination on the
outer edges that correspond to the bands on the page. Check the
charge links and arms for proper operation, binds or incorrectly
mounted counterbalance springs. Repair or replace as necessary.
3
HVPS
Check the following voltages at J15-8 on the system board:
• Printer Idle
J15-8 measures 0 V dc
• Printer Printing Test Page
J15-8 voltage changes from 0 V dc to +4 V dc
If the voltage does not vary, check the continuity of line J15-8 in the
front cable harness. If there is no continuity, replace the cable
harness. If there is continuity, replace the HVPS. If this does not
correct the problem, replace the system board.
Turn the printer off, and check the resistance between J15-7 and
printer ground. The resistance measures approximately 0 ohms. If
incorrect, make sure the system board is mounted correctly and
securely grounded. If correct, replace the system board.
FRU
Action
1
Hot roll fuser assembly
Check the fuser assembly for toner contamination. The hot roll
especially might cause toner to be retained and deposited on the
page.
Summary of Contents for X642E
Page 15: ...Laser notices xv 7002 xxx Japanese Laser Notice ...
Page 16: ...xvi Service Manual 7002 xxx Korean Laser Notice ...
Page 305: ...Repair information 4 45 7002 xxx 5 Remove the four screws C 6 Remove the hard disk ...
Page 400: ...4 140 Service Manual 7002 xxx ...
Page 402: ...5 2 Service Manual 7002 xxx Sensors ADF Model X642e Models X644e X646e ...
Page 432: ...5 32 Service Manual 7002 xxx ...
Page 436: ...6 4 Service Manual 7002 xxx ...
Page 438: ...7 2 Service Manual 7002 xxx Assembly 1 Covers printer model X642e ...
Page 440: ...7 4 Service Manual 7002 xxx Assembly 1 continued Covers printer model X642e ...
Page 442: ...7 6 Service Manual 7002 xxx Assembly 2 Cover printer models X644e and X646e ...
Page 444: ...7 8 Service Manual 7002 xxx Assembly 3 Covers ADF scanner ...
Page 446: ...7 10 Service Manual 7002 xxx Assembly 4 Frame 1 ...
Page 448: ...7 12 Service Manual 7002 xxx Assembly 5 Frame 2 ...
Page 450: ...7 14 Service Manual 7002 xxx Assembly 6 Frame 3 ...
Page 456: ...7 20 Service Manual 7002 xxx Assembly 11 Scanner ADF sensors ...
Page 458: ...7 22 Service Manual 7002 xxx Assembly 12 Scanner flatbed ...
Page 462: ...7 26 Service Manual 7002 xxx Assembly 15 Paper feed multipurpose feeder ...
Page 464: ...7 28 Service Manual 7002 xxx Assembly 16 Paper feed alignment ...
Page 466: ...7 30 Service Manual 7002 xxx Assembly 17 Integrated 500 sheet paper tray ...
Page 468: ...7 32 Service Manual 7002 xxx Assembly 18 Drives Main drive and developer drive ...
Page 470: ...7 34 Service Manual 7002 xxx Assembly 19 Hot roll fuser ...
Page 472: ...7 36 Service Manual 7002 xxx Assembly 20 Transfer charging ...
Page 474: ...7 38 Service Manual 7002 xxx Assembly 21 Electronics power supplies ...
Page 476: ...7 40 Service Manual 7002 xxx Assembly 22 Electronics card assemblies ...
Page 482: ...7 46 Service Manual 7002 xxx Assembly 27 Cabling diagram 4 model X642e ...
Page 484: ...7 48 Service Manual 7002 xxx Assembly 28 Cabling diagram 4 models X644e X646e ...
Page 486: ...7 50 Service Manual 7002 xxx Assembly 29 Cabling diagram 5 1 2 3 3 3 4 5 ...
Page 488: ...7 52 Service Manual 7002 xxx Assembly 30 Cabling diagram 6 model X642e ...
Page 490: ...7 54 Service Manual 7002 xxx Assembly 31 Cabling diagram 6 models X644e X646e ...
Page 500: ...7 64 Service Manual 7002 xxx Assembly 40 Envelope feeder 1 ...
Page 502: ...7 66 Service Manual 7002 xxx Assembly 41 High capacity feeder 1 ...
Page 508: ...7 72 Service Manual 7002 xxx ...
Page 523: ...Lexmark X644e X646e Wiring diagram AIO printer ...
Page 524: ...Lexmark X642e Wiring diagram AIO scanner ...
Page 525: ...Lexmark X644e X646e Wiring diagram AIO scanner ...