Photo 32

Photo 33

Photo 34

Photo 35

Photo 36

6

Lexmark E232/330/332  Technical Instructions

E-mail: [email protected]   

Website:

www.futuregraphicsllc.com 

Step 7

Remove the two screws holding the wiper
blade.

(See Photo 34)

Step 8

Remove the wiper blade.

(See Photo 35)

Clean the waste hopper and wiper blade
using dry compressed air or a vacuum.

Step 9

Apply padding powder to the wiper
blade. Place the blade into the waste hop-
per and install the two screws that hold
the blade in place.

(See Photo 36)

Step 11

Place the waste hopper so that it is facing
towards you. Apply padding powder to
the drum and place the drum in the hop-
per so the drive gear is on the left side of
the cartridge.

(See Photo 38)

Step 10

Clean the PCR saddles using a cotton
swab and alcohol. Place the saddles onto
the ends of the PCR and place the PCR
back into the waste hopper.

(See Photo 37)

Step 5

Remove the drum.

(See Photo 32)

If you plan on reusing the drum,
clean the drum with a soft lint-
free cloth and place the drum in
a protected area out of the light.

Step 6

Grasp the PCR contact saddles
and lift the PCR from the waste
hopper.

(See Photo 33)

Clean the

PCR using a dry lint-free cloth.

Photo 37

Photo 38

Summary of Contents for E 330

Page 1: ...4 9900 Int l 1 818 837 8100 FAX 1 800 394 9910 Int l 1 818 838 7047 DALLAS USA US 1 877 499 4989 Int l 1 972 840 4989 FAX 1 877 774 1750 Int l 1 972 840 1750 ATLANTA USA US 1 877 676 4223 Int l 1 770...

Page 2: ...another engine Visit www futuregraphicsllc com 2 Lexmark E232 330 332 Technical Instructions Step 9 Slide the contact bushing off the developer roller axle See Photo 10 Step 10 While holding the shaf...

Page 3: ...the doctor bar using compressed air or a vacuum Clean the contact edge of the bar using a cotton swab and Acetone See Photo 14 Step 14 Remove the cartridge warranty sticker from the side of the cartri...

Page 4: ...ar onto the end of the cartridge See Photo 23 Step 23 Place the doctor bar tension spring onto the top of the doctor bar so the arrow is facing away from the hopper Place the white tabs onto the docto...

Page 5: ...Step 1 Remove the two screws one on each end of the cartridge that hold the toner hopper locking mechanism See Photos 27 28 Step 2 Step 2 Remove the locking mechanism See Photo 29 Photo 29 Photo 30 P...

Page 6: ...e Photo 36 Step 11 Place the waste hopper so that it is facing towards you Apply padding powder to the drum and place the drum in the hop per so the drive gear is on the left side of the cartridge See...

Page 7: ...tarting on the drive gear side See Photo 39 Photo 41 Step 13 Install the E clip onto the small gear side of the drum axle See Photo 40 Step 14 Install the toner hopper locking mecha nism onto the wast...

Page 8: ...pm and replaces both the E312 and E323 machines Lastly the E332n and E332nt sell for 499 and 599 respectively and are both network capable The E332nt comes with an extra paper tray In May 2004 Dell re...

Reviews: