DC power: Power: DC9V
Static current: <10uA
Alarm current: <12mA
Low voltage alarm: 6.5V~7.5V
AC power: Power: 100-130V/AC
220-240V/AC
Current: <25 mA
Alarm
>85 db (3m)
Working temperature: -10
~50
°C
1. At first, you need install them in your bedroom and routeway, and should install one item in
every bedroom at least.
2. Stairway is important for you to rush out when fires occur, so there must install smoke
detectors.
3. You at least require one smoke alarm on every floor,including finished attics and basements.
4. Install one alarm beside every electric facility.
5. Install smoke alarms in the middle of ceiling,because smog,heat and flashes always lift to the
top of rooms.
6. If some reasons cause you can’t install them in the middle of ceiling,you need to install them
at least 10cm away from the wall.
7. If you like to install them on the wall, they should be installed 10-30.5cm away under the
ceiling. Diagram 1.
8. You need install more than one alarm when the length of your hall exceeds 9m.
9. In an ablique roof room,install the alarm 0.9m away from the top.Diagram 2.
10. How to install smoke alarms in a removable house.The removable house is short of heat
isolation, so you’d better install the alarm 10-30.5cm away from the ceiling.for safety you need
install another one near your bedroom, too.
Summary
The product is photoelectric smoke alarm, it is generally more effective at detecting smoldering
fires which smolder for hours before bursting into flame.Sources of it fires may include cigarettes
burning in couches or bedding. It accords with the ISO/DIS 12239 Standard.
IMPORTANT! PLEASE READ CAREFULLY AND KEEP IT.
This user’s manual contains important information about your smoke alarm’s operation. To
insure your safety, you need install one alarm at least in your every single room. Please don’t
open the smoke alarm for that may cause improper effect. If you are installing this smoke alarm
for use by others, you must leave this manual –or a copy of it—with the end user.
Specifications
Where fit to install smoke alarm
volume:
BEST HERE
CEILING
10
C
M
(4
'')
30
.5
C
M
(1
2'
')
SIDE WALL
M
A
X
IM
U
M
ACCEPTABLE HERE
NEVER HERE
M
IN
IM
U
M
MINIMUM
10CM(4'')
DIAGRAM 1
IN THIS AREA
0.9M(3ft)
0.9M(3ft)
FROM PEAK
HORIZONTAL DISTANCE
ANYWGERE
DIAGRAM 2
Power frequency: 50/60Hz