DC power: Power: DC9V

Static current: <10uA

Alarm current: <12mA
Low voltage alarm: 6.5V~7.5V

AC power: Power: 100-130V/AC

220-240V/AC

Current: <25 mA

Alarm

>85 db (3m)

Working temperature: -10

 

~50

 

°C

 

1. At first, you need install them in your bedroom and routeway, and should install one item in 

every bedroom at least.

2.  Stairway  is  important  for  you  to  rush  out  when  fires  occur,  so  there  must  install  smoke 

detectors.

3. You at least require one smoke alarm on every floor,including finished attics and basements.

4. Install one alarm beside every electric facility.

5. Install smoke alarms in the middle of ceiling,because smog,heat and flashes always lift to the 

top of rooms.

6. If some reasons cause you can’t install them in the middle of ceiling,you need to install them 

at least 10cm away from the wall.

7. If you like to install them on the wall, they should be installed 10-30.5cm away under the 

ceiling. Diagram 1.

8. You need install more than one alarm when the length of your hall exceeds 9m.

9. In an ablique roof room,install the alarm 0.9m away from the top.Diagram 2.

10. How to install smoke alarms in a removable house.The removable house is short of heat 

isolation, so you’d better install the alarm 10-30.5cm away from the ceiling.for safety you need 

install another one near your bedroom, too.

Summary

The product is photoelectric smoke alarm, it is generally more effective at detecting smoldering 

fires which smolder for hours before bursting into flame.Sources of it fires may include cigarettes 

burning in couches or bedding. It accords with the ISO/DIS 12239 Standard.

IMPORTANT! PLEASE READ CAREFULLY AND KEEP IT.

 

This  user’s  manual  contains  important  information  about  your  smoke  alarm’s  operation.  To 

insure your safety, you need install one alarm at least in your every single room. Please don’t 

open the smoke alarm for that may cause improper effect. If you are installing this smoke alarm 

for use by others, you must leave this manual –or a copy of it—with the end user.

Specifications

Where fit to install smoke alarm

volume:

BEST HERE

CEILING

10

C

M

(4

'')

30

.5

C

M

(1

2'

')

SIDE WALL

M

A

X

IM

U

M

ACCEPTABLE HERE

NEVER HERE

M

IN

IM

U

M

MINIMUM

10CM(4'')

DIAGRAM 1

IN THIS AREA

0.9M(3ft)

0.9M(3ft)

FROM PEAK

HORIZONTAL DISTANCE

ANYWGERE

DIAGRAM 2

Power frequency: 50/60Hz