Sensor information
180°/140°
This product is very convenient to install, choose a suitable position for precise installation, try not to install the sensor
in a place with large environmental interference; for example, air conditioning port, heat source port and other
locations. Because these positions are likely to cause the sensor to malfunction, after selecting the installation
position and correctly connecting the power cable to the load cable, the power can be turned on.
1. Firstly, adjust the TIME to the minimum , then adjust the LUX to the maximum (the working position during the
day) and test the induction.
2. If the sensor has been illuminated during the test, there is no one in front of the sensor. It must wait until the lamp
is turned off, and it will be triggered by the human body movement again after 5 seconds. If there is always someone
moving the light in the middle, it will always be on and cannot be turned off.
3. After the above preliminary test is normal, you can choose the appropriate LUX value and delay time.
Installation and precautions
Installation
1
、
Shut off power;
2
、
Loosen the screw on the bottom lid, open the wiring hole, pass the wire of power and load through the
bottom lid;
3
、
Fix the bottom lid with inflated screw on the selected position;
4
、
Connect the power and load wire into connection-wire column according to the connection-wire diagram;
5
、
Put the sensor on the bottom lid, twist the screw tightly then electrify it and test it.
Connection-wire diagram
Brown
Blue
’ Red
connect and with power;
connect and with load.
N
N
L’
L
L
L
N
L
L’
Brown
Blue N
in
Red
out
Sensor
Load
~
Detection range
(
22
℃)
Detection angle