LEXIBOOK MeteoClock SM1120 Owner'S Manual Download Page 5

Copyright © Lexibook  2004 

5

SYNCHRONIZATION

Automatic Learn Function

Learn function executes automatically and runs for

approximately 3 minutes when batteries are first

installed in the receiver.  
Within these 3 minutes, receiver picks up the temperature & humidity signals from remote
transmitter and displays the readings.

Manual-Learn (Searching for Remote Signals)

If a new remote transmitter is added or if signal is lost (outdoor display blinking), learn function must
be executed again.  

Press & hold 

ALARM/AM/PM/°C/°F

for 3 seconds to start.

Beep sound indicates that learn function has started.   

CHANNEL symbol will flash and unit will beep as each transmitter is

detected.

Temperature & humidity readings of remote transmitter displays on the

receiver.   

Press & hold 

Channel

for 3 seconds to start auto channel scroll function. In this mode, the

display will scroll through the data from all the valid channels, each of which will be shown for
8 seconds. Press & hold 

Channel

for 3 seconds again to disable this function. 

SETUP

Summary of Contents for MeteoClock SM1120

Page 1: ...k but also the actual weather The MeteoClock SM1120 incorporates different functions Thermometer Temperature is displayed in real time to the nearest tenth of a degree Celsius Thanks to its wireless s...

Page 2: ...to 4 remote transmitter via RF technology of 433MHz minimum and maximum temperature record high low temperature alarm function temperature and humidity trend indicator weather report symbols LED Backl...

Page 3: ...time alarm and temperature alarm set points high low activates alarm snooze UP HOUR MAX scrolls through hours shows maximum temperature enables and disables backlight DOWN MINUTE MIN scrolls through...

Page 4: ...ransmitters Insert batteries to start setup HOUSE CODE will flash for 8 seconds Select HOUSE CODE 1 15 by pressing C F and then press SET Transmitters for each receiver must be set to the same HOUSE C...

Page 5: ...signal is lost outdoor display blinking learn function must be executed again Press hold ALARM AM PM C F for 3 seconds to start Beep sound indicates that learn function has started CHANNEL symbol wil...

Page 6: ...een 12 or 24 hour format Alarm setting Select alarm mode using MODE SNOOZE Select hour using UP HOUR MAX Select minute using DOWN MINUTE MIN In alarm mode press ALARM to toggle alarm On and Off When a...

Page 7: ...and humidity readings will alternately display on the receiver C or F Temperature Display Toggle between C and F by pressing ALARM PM AM C F in clock mode Min and Max Temperature Press DOWN MINUTE MI...

Page 8: ...eze Warning Snow symbol will flash to warn of snowing Activated when Channel 1 s temperature is between 1 9 C and 2 9 C Snow will appear solid if and when Channel 1 s temperature falls below 1 9 C it...

Page 9: ...mperature limit value To disable particular alarm press ALARM PM AM C F dashes alarm disabled Press MODE SNOOZE to finish Repeat steps to for all other channels if desired Low temperature alarm Scroll...

Page 10: ...high low temperature alarm Select high low temperature alarm set point using MODE SNOOZE Press ALARM PM AM C F to clear value Press MODE SNOOZE to finish setting To view maximum temperature Toggle bet...

Page 11: ...es Temperature may be below 30 C Batteries in remote transmitter may need changing Move remote transmitter closer to the receiver Make sure remote transmitter is away from sources of electrical distur...

Page 12: ...e warranty or the after sales service please contact your retailer and supply proof of purchase Our warranty covers material or installation related defects attributable to the manufacturer with the e...

Reviews: