High-pass filter indications
⑤
·
The currently active high-pass setting is illuminated.
Setting a high-pass filter
·
High-pass filters can be set by briefly pressing the noiseless high-pass filter push button
⑥
. Settings are: Off, 12 dB / octave at 40 Hz and
6 dB / octave at 300 Hz. High-pass filters eliminate unwanted low frequency noise such as structure borne noise.
Key-lock function
The noiseless push buttons of the microphone can be locked and unlocked by constantly pressing the key-lock push button
②
for more than 2
seconds.
Automatic attenuation function
The microphone will automatically adjust to the next higher attenuation level if it experiences clipping due to a high SPL. The microphone
enters and leaves the automatic attenuation mode by constantly pressing the attenuation push button
④
for more than 2 seconds. The
microphone is set to automatic attenuation mode if the status indicator
①
is illuminated in red. Please note that the microphone will need
around half a second to adjust to the new attenuation level.
Using the mic
LCT 540
06
Summary of Contents for LCT 540 Authentica
Page 1: ...www lewitt audio com EMPHASIZE THE IN YOUR GENUINE SOUND LCT 540...
Page 8: ...Tech data LCT 540 Dimensions 52 158 Tech graph dB ref 1V Pa 3 dB unit 08...
Page 10: ...Accessories LCT 540 Accessories LCT 40 x W AIu case LCT 40 SHx DTP 40 Lb 10...
Page 14: ...Mooslackengasse 17 1190 Vienna AUSTRIA info lewitt audio com 14...
Page 15: ......