Installing a controller
• TO AVOID FIRE SHOCK OR DEATH; TURN OFF POWER at a circuit breaker
or fuse panel and test that power is off before wiring in a Levven Controls
product. Install and/or use Levven Controls in accordance with local electrical
codes and regulations. Levven controllers are to be mounted in an electrical
junction box of suitable size to satisfy the electrical code in your area. If you
are unsure about any part of these instructions, consult a qualified electrician.
1) Connect wires to the controller (Fig 1)
a. Connect the black power wire to the black wire of the controller
b. Connect the black load wire to the red wire from the controller
c. Connect the white wires from the power, load, and controller together
2) Mount the controller in an electrical box
a. If installing the controller in a steel box, position the controller’s antenna
wire outside the box for best reception. The antenna can be inside a plastic
electrical box without affecting reception.
3) Turn power on
a. When your connections are safely completed, energize the circuit by turning
the power on at the panel.
b. When powered, the LED status indicator on the controller will illuminate.
4) Group controllers together
a. When two or more controllers are installed in a building, grouping controllers
together is required to operate multiple controllers from one switch or using
Levven Q for mobile device access and control. Only controllers with no
previously saved group or pairing can join a group.
b. Press and release the ‘Pair’ button on one of the controllers in the group (or
an ungrouped controller to start a new group). The LED on this controller
(C1) will blink green.
c. Press ‘Pair’ button on new controller being added to the group (C2). Its LED
will blink green, and the first controller’s LED will blink red/green.
d. Press ‘Pair’ button on the first controller (C1) again to complete the grouping.
Its LED will flash green three times to confirm the group setting was saved.
5) How to reset a controller
a. To clear switch pairings from a controller, press and hold the ‘Pair’ button for
5 seconds. The LED will flash red three times to confirm.
b. To remove a controller from a group, press and hold its ‘Pair’ button for 10
seconds. The LED will flash red 10 times when the grouping is cleared.
c. If using multiple controllers, group the controller before pairing it to a switch.
6) Pair switches and controllers
a. Press and release the ‘Pair’ button on the controller. The LED on the
controller will blink green. NOTE: If there is no pairing request received within
60 seconds, the controller will quit the pairing procedure and its LED will
return to a solid green.
b. Squeeze then quickly release both ends of the switch to send a pairing code
to the controller. The LED on the controller will blink green and red.
c. Press and release the controller’s ‘Pair’ button to confirm the pairing. Its LED
will flash green to confirm the pairing was saved successfully.
7) Mounting and using switches
a. Levven Controls switches can be secured to any surface. Screws and
anchors are provided to mount switches. Use decorator-style or Designer
Series wall plates to finish the installation.
b. Press and release the top of the switch rocker to send an “on” command to
the controller. Press and hold the top to brighten the lights, or press and hold
the bottom of the switch to dim the lights. Press and release the bottom of
the switch rocker to send an “off” command.
Setting maximum and minimum brightness
1) Set the dimmer’s max brightness level
a. Press and hold the top of the switch rocker to increase the light’s brightness.
Fi
gur
e 1
Connecting
the
controller
to
the
line/hot,
load,
and
neutral
wires.
Connectez le contrôleur avec les fils de la ligne actif,
le
charge,
et le neutre. Conexión del controlador de carga con los cables de la línea fase,
carga y neutro.
If the light flickers, release the switch. Press and hold the bottom of the
switch rocker to dim the light to a level where it does not flicker.
b. 2-click/double-click the button on the GDT15 controller. This sets the
highest brightness. The GDT15 controller’s LED indicator will flash green to
confirm the setting is saved.
2) Set the dimmer’s min brightness level
a. Press and hold the bottom of the switch rocker to decrease the light’s
brightness. If the light flickers, release the switch. Press and hold the top of
the switch rocker and brighten the light to a level where it does not flicker.
b. 2-click/double-click the button on the controller. This sets the lowest
brightness. The GDT15 controller’s LED indicator will flash green to confirm
the setting is saved.
3) Reset the dimmer’s max/min brightness level to
factory default
a. 3-click/triple-click the button on the GDT15 controller. NOTE: This will not
clear any pairings or groupings in the controller’s memory. It only resets the
brightness max/min settings to factory defaults.
Further Assistance
Support documents, videos, and 1-year limited manufacturer warranty
information is available at levven.com/support. Levven Controls and GoConex by
Levven are proudly designed and manufactured in Canada. Telephone Levven
Electronics Ltd (780) 391-3000 or email [email protected].
Levven Controls GDT15 dimming controller /
contrôleur
Input
/ Alimentation
: 85-265VAC, 50/60Hz 0.1~1.5A. Load
/ Chargement
:
1) Black wire connected to Line/Hot
File noir connecte avec la ligne actif
Cable negro conectado a la línea fase
2) Red wire connected to load
File rouge connecte avec le chargement
Cable rojo conectado a la linea de carga
3) White wire connected to both line and load neutrals
File blanc connecte avec les deux ligne et le chargement neutre
Cable blanco conectado a la dos líneas y a la carga neutra
To Load
Pour chargement
Para cargar
Antenna wire
Fil de l’antenne
Cable de antena
Electrical box
Boîte de jonction
Caja de conjunción
LED status indicator
Indicateur DEL
Indicador DEL
‘Pair’ button
Boutton “Jumelage”
Botón “Acoplar”
From Line Power
Pour ligne d’alimentation
Entrada linea de alimentación
Line
/ Ligne / Línea
Neutral (white)
/ Neutre (blanc) / Neutro (blanco)
Hot (black)
/ Actif (noir) / Fase (negro)
Load
Charge
Carga
Red
Rouge
Rojo
White
Blanc
Blanco
Black
Noir
Negro
1.5A max (resistive lighting
/ résistance de l’éclairage
). Indoor use only
/
Utilisation intérieur seulement
. Operating temperature range
/ S’opère à une
température ente
-40°C – 50°C. FCC ID : 2ADH9-G2CF. This device complies
with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may
cause undesired operation. IC ID: 12453A-G2CF. CAN ICES-3(B)/NMB-3(B).
Certified to
/ Certifié à
CSA STD C22.2 #14 Conforms to
/ Conforme à
UL STD
244A & 508
Levven Controls GSW switch
FCC ID: 2ADH9-GSW IC ID: 12453A-GSW
FR
Installation du contrôleur Levven
• POUR ÉVITER LES DÉCHARGES ÉLECTRIQUES OU LA MORT; COUPEZ
L’ALIMENTATION au niveau d’un disjoncteur ou d’un panneau de fusibles et
vérifiez qu’il est bien hors tension avant de brancher des produits Levven.
Installez et/ou utilisez Levven en accord avec le code local d’électricité et ses
règlements. Le contrôleur Levven doit être inséré dans une boîte de jonction
appropriée et en conformité avec le code électrique de votre région. Si vous
n’êtes pas sûr de bien comprendre une partie de ces instructions, consultez
un électricien qualifié.
1) Vous aurez besoin de fils pour installer le
contrôleur Levven (Fig. 1)
a. Connectez le fil d’alimentation noir au fil noir du contrôleur.
b. Connectez le fil de charge noir au fil rouge du contrôleur.
c. Connectez ensemble les fils blancs de l’alimentation, de la charge et du