User Manual for PuraLev
®
200MU
www.levitronix.com
PL-4031-00, Rev07, DCO# 20-144
13
3.4 Thermal Management
3.4.1 Motor Temperature
The motor temperature depends on the ambient and liquid temperature, as well as on the hydraulic
operation point.
illustrate the temperature characteristics of the motor
depending on these parameters. For higher liquid temperatures and hydraulic operating points active cooling
is recommended for example with the air cooling module
ACM-1.1
).
Figure 14: Temperature curves for the BSM-1.x motor @ 25 C liquid temperature
(Pump head LPP-200.16 and representative for LPP-200.17, temperature measured inside of the motor, contact temp. of surface is below this temp.)
Figure 15: Temperature curves for the BSM-1.x motor @ 70 C liquid temperature
(Pump head LPP-200.16 and representative for LPP-200.17, temperature is measured inside of the motor, contact temp. is below this temp.)
77
97
117
137
157
177
197
0.0
1.0
2.0
3.0
4.0
5.0
25
35
45
55
65
75
85
95
0.0
2.5
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
[F]
[gallons/min]
[°C]
[liters/min]
Ambient Temp = 25
C
Liquid Temp. = 25
C
Viscosity = 0.7 cP
10000 rpm
9000 rpm
8000 rpm
7000 rpm
6000 rpm
Absolute Temperature Limit
Recommended
Operational Limit
---- 48 VDC Supply
24 VDC Supply
77
97
117
137
157
177
197
0.0
1.0
2.0
3.0
4.0
5.0
25
35
45
55
65
75
85
95
0.0
2.5
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
[F]
[gallons/min]
[°C]
[liters/min]
Ambient Temp = 25
C
Liquid Temp. = 70
C
Viscosity = 0.7 cP
---- 48 VDC Supply
24 VDC Supply
4000 rpm
9000 rpm
7000 rpm
6000 rpm
5000 rpm
8000 rpm
Absolute Temperature Limit
Recommended Operational Limit