User Manual for BPS-4H (High Temp.)
www.levitronix.com
PL-2009-03, Rev04, DCO# 21-101
32
6.2 Replacement Interval of the Impeller
The impeller has a limited lifetime depending on the chemical type, concentration and temperature of the fluid
which is pumped. Therefore, a preventive periodical exchange of the impeller is recommended. Contact the
Levitronix Technical Service Department
(see
Section 8
) for further information on replacement times.
6.3 Impeller Replacement Procedure for Pump Head CP-4.25
6.3.1 Preparation
Before starting the impeller exchange procedure,
the parts and tools illustrated in
prepared. Impeller exchange kits, which contain this
parts and tools, are available at
Levitronix
®
(see
Figure 33: Parts of pump head CP-4.25
A-E: Parts of impeller exchange kit IEK-4.6
a-d: Other parts of pump head
The following warnings and cautions should be read
carefully before starting the exchange of the
impeller.
!
WARNING
The impeller could splash toxic or corrosive chemicals
because of the strong magnetic forces. Flush the
pump housing before opening it.
!
WARNING
Harmful chemicals may be present.
Skin contact and toxic gases may be hazardous to
your health. Wear safety gloves and other appropriate
safety equipment.
!
CAUTION
The rotating impeller could cause injury. Do not run the
pump system when opening the pump head.
CAUTION
Pay attention to the magnetic forces when handling the
impeller. The attraction of magnetic parts and particles
should be avoided in order to keep the impeller and the
pump head clean and free of contamination.
Impeller
IMP-4.7
Sealing O-Ring for
Pump Casing
8 pcs. M8x40 (SS/PTFE)
Pump Head Screws
Torque Spec.: 1.2 Nm
4 pcs. M8x30
(SS/PTFE)
Motor Screws
Torque Spec.: 1.2 Nm
Impeller Exchange
Tool IET-3.1
A
B
C
D
E
Casing Lid
a
Casing Bottom
b