background image

Single Pole (One location) or 3-Way (Multi-location) 

Magnetic Low-Voltage Dimmer

Cat. No. VZMØ6-1L, 600VA (Lighted) 

120VAC, 60Hz

INSTALLATION INSTRUCTIONS

DI-000-VZM06-02C

If installing Dimmer in a single device application, proceed with the 

INSTALLINg yOUR DIMMeR

 section. If installing Dimmer in a 

multi-device application, proceed as follows:

MULTI-DeVICe AppLICATION

In multi-dimmer installations, the reduction of the dimmer’s capacity 

is required. Refer to the chart for maximum load per dimmer.

MAXIMUM BULB WATTAge

Low-voltage dimmers are rated in Volt-Amps (VA). The maximum 

bulb wattage is determined by the efficiency of the transformer in the 

low-voltage lighting system. Transformer efficiencies will vary from 

different manufacturers; consider 75% efficient as average. Use the 

chart to determine maximum bulb wattage for typical transformer 

efficiency ratings.

INSTALLINg yOUR DIMMeR

NOTe: 

Use check boxes          when Steps are completed.

WARNINg:

 

TO AVOID fIRe, ShOCk, OR DeATh; 

TURN Off pOWeR

 at circuit breaker or fuse and test 

that power is off before wiring!

Identifying your wiring application 

(most common):

NOTe:

 If the wiring in the wall box does not resemble any 

of these configurations, consult a qualified electrician.

ON

Off

ON

Off

ON

Off

ON

Off

ON

Off

ON

Off

ON

Off

ON

Off

ON

Off

ON

Off

ON

Off

ON

Off

 Step 1

WIRINg DIMMeR:

Connect wires per WIRINg DIAgRAM as follows:

WARNINg:

 

CONNECT A MAGNETIC LOW-VOLTAGE DIMMER

ONLY TO THE PRIMARY (HIGH-VOLTAGE) SIDE OF A MAGNETIC
LOW-VOLTAGE TRANSFORMER.

  Green or bare copper wire in wall box to Green terminal screw.

• 

Line Hot wall box wire to terminal screw marked “BK”.

• 

Load wall box wire to terminal screw marked “RD”.

•   

Dimmer terminal screw marked “YL/RD” should have Red 

insulation label affixed. 

   NOTe: 

If insulating label is not affixed to terminal screw marked 

“YL/RD”, use electrical tape to cover.

•  proceed to Step 5

hot (Black)

Neutral (White)

Load

Dimmer

Bk

Black

White

RD

green

ground

Line 

120VAC, 60hz

yL/RD

Use Terminal for 3-Way or

More Applications Only.

for Single-pole Applications,

Do Not Remove This Label.

(pRIMARy SIDe Of

MAgNeTIC LOW-VOLTAge 

TRANSfORMeR)

}

Bk

yL/RD RD

Terminal

Screw marked

Black (Bk)

Terminal

Screw marked

Red (RD)

Terminal

Screw marked

yellow/Red

(yL/RD)

Terminal Label:

Use Terminal for 3-Way or More Applications Only.

for Single-pole Applications, Do Not Remove This

Label.

4

3

2

1

•  Make sure that the ends of the wires from the wall box are 

 

  straight (cut if necessary)

.

•  Remove insulation from each wire in the wall box as shown.
• 

for Single-pole Application, go to Step 4a.

• 

for 3-Way Coordinating Remote (no LeDs) Application, go  

  to Step 4b.

• 

for 3-Way Matching Remote (with LeDs) Application, go to  

  Step 4c.

WARNINgS AND CAUTIONS:

•  To be installed and/or used in accordance with appropriate electrical codes and regulations.
•  If you are unsure about any part of these instructions, consult a qualified electrician.
•  To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformer- 

  operated appliance.
•  Use with magnetic low-voltage transformers, incandescent, or 120V halogen fixtures only. Use a Leviton electronic low-voltage dimmer to control electronic (solid  

  state) low-voltage transformers.
•  When magnetic low-voltage circuits are operated at a dim level, with all lamps inoperative, excess current may flow through the transformer. To avoid possible 

transformer failure due to overcurrent, use a transformer that incorporates thermal protection or a fuse at the primary windings.

•  Vizia™ dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia™ remotes for multi-location dimming.

WARNINgS AND CAUTIONS:

•  Use only one (1) Vizia™ dimmer in a multi-location circuit with up to 9 coordinating remotes without LEDs or up to 4 matching remotes with LEDs. The remote(s) will turn 

the light on at the brightness level selected at the dimmer.

•  Total minimum load must exceed 40W.
•  Dimmer may feel warm to the touch during normal operation.
•  Recommended minimum wall box depth is 2-1/2”.
•  Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.
•  Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
•  Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.

2

4

3

1

Single-pole

1. 

Line (Hot)

2. 

Neutral

3. 

Ground

4. 

Load

IMpORTANT:

 For 3-Way applications, note that one of the screw 

terminals from the old switch being removed will usually be a 

different color (Black) or labeled Common. Tag that wire with 

electrical tape and identify as the common (Line or Load) in both the 

dimmer wall box and remote wall box.

Strip gage 

(measure bare 

wire here or use 

gage on back of 

the dimmer)

5/8”

(1.6 cm)

Cut

(if necessary)

Bl

Back Wire (either hole may 

be used)

Back wire openings use #14-12 

AWG solid copper wire only.

Side Wire Connection

Side wire terminals accept 

#14 AWG solid copper wire only.

3-Way Wiring with Coordinating 

Dimming or Switching Remote 

(no LeDs) Application:

hot (Black)

Neutral (White)

Load

Dimmer

Coordinating Remote (no LeDs)

yL/RD

yL/RD

RD

Wh

RD

Bk

Bk

Black

Do not use for

incandescent

applications.

White

Line 

120VAC, 60hz

green

ground

green

ground

(pRIMARy SIDe Of

MAgNeTIC LOW-VOLTAge 

TRANSfORMeR)

}

push in side at 

tab to release

Line up tabs and 

press in side to attach

  

   

   

More than  

  Cat. No. 

 Single 

Two Devices  2 Devices

   VZMØ6 

  600VA 

   500VA 

400VA

MAXIMUM LOAD peR DIMMeR fOR MULTI-DeVICe

Bk

yL/RD RD

Bk

yL/RD RD

4

3

2

1

5

Terminal

Screw marked

Black (Bk)

Terminal

Screw marked

Red (RD)

Terminal

Screw marked

yellow/Red

(yL/RD)

Coordinating Remote

2

4

3

5

1

Dimmer

(Coordinating Dimming Remote Depicted)

  

  

            

 Two    More than  

            Rating               Single        gang

    

  2 gang

   

         600VA                  450W 

 375W       300W

MAXIMUM BULB WATTAge AT 75% effICIeNCy

2

4

1

5

3

3-Way

1.   

Line or Load 

(See important instruction below)

2. 

Neutral

3. 

Ground

4. 

First Traveler – note color

5. 

Second Traveler – note color

NOTe:

 For matching remote w/LEDs installation, 

the 

first

 

Traveler

 becomes Line Hot.

 Step 2 cont’d

 Tools needed to install your Dimmer:

Slotted/Phillips Screwdriver 

Electrical Tape 

Pliers  

 

 

Pencil 

Cutters 

 

 

Ruler

Changing the color of your Dimmer:

Your Dimmer includes three color options. The Dimmer ships with 

the White frame attached. To change color of frame, proceed as 

follows:

 Installing Dimmer by itself or with other devices:

 Step 2

preparing and connecting wires:

This dimmer can be wired using side wire terminal 

screws or through backwire openings. Choose 

appropriate wire stripping specifications accordingly.

 Step 3

Single-pole Wiring Application:

 Step 4a

 Step 4b

WIRINg DIMMeR:
Connect wires per WIRINg DIAgRAM as follows:

WARNINg:

 

FOR MAGNETIC LOW-VOLTAGE APPLICATIONS, 

CONNECT DIMMER ONLY TO THE PRIMARY (HIGH-VOLTAGE) 

SIDE OF A MAGNETIC LOW-VOLTAGE TRANSFORMER.

NOTe:

 When using the coordinating remote without LEDs, the 

dimmer can be installed on either the Line or Load side of the 

3-way circuit.

NOTe: 

Maximum wire length from dimmer to all installed remotes 

cannot exceed 300 ft.

  Green or bare copper wire in wall box to Green terminal screw.

•   

Line Hot (common) wall box wire identified (tagged) when 

removing old switch to terminal screw marked “BK”.

•   

First Traveler wall box wire to terminal screw marked “RD” 

(note wire color)

. This traveler from the dimmer must go to the 

terminal screw on the remote marked “RD”.

•   

Remove Red insulating label from terminal screw marked 

“YL/RD”.

•   

Second Traveler wall box wire to terminal screw marked 

“YL/RD” 

 (note wire color)