Air-Gap Switch:
On the dimmer only, engage
the air-gap switch by gently pulling the bottom
of the push pad until it lifts mcompletely
out of the frame and a click is heard and all
LED’s are OFF
(refer to Figure)
. This will cut
power to the fixture to replace the bulb. After
servicing is complete, push the push pad back
for normal operation.
Cleaning:
Clean with a damp cloth.
DO NOT
use chemical cleaners.
Mode 1 – Set Minimum Brightness:
Set the minimum brightness
level that the lights can dim to prior to turning full OFF.
Mode 2 – Set Dim-Lock
: Set the brightness level that the lights will
turn on to regardless of the previous light level at which they were
turned OFF.
Mode 3 – Set Fade Rate:
Set the amount of time (in seconds) that
the lights will have to turn ON or OFF. Fade rates can be set to one
of 7 different settings.
This equipment has been tested and found to comply with the
limits for a Class B Digital Device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment
OFF and ON, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving Antenna.
• Increase the separation between the equipment and
the receiver.
• Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
• Consult the dealer or an experienced radio/tv technician for help.
ADVANCED PROGRAMMING FEATURES
To Program:
NOTE:
Have a flashlight handy if this dimmer
controls the only light source in the room.
1.
On the dimmer only, engage the air-gap
switch by gently pulling the bottom of the
push pad until it lifts completely out of the
frame and a click is heard and all LED’s
are OFF.
2.
Press push pad back into frame and hold
push pad for 7 seconds until the locator
light and the top LED (LED 1) starts
blinking.
3.
Upon releasing the push pad, the locator
light will continue to blink once per second
indicating the dimmer is in Mode 1, Set Minimum Brightness mode.
To change the current Minimum Brightness level from 1-50%, use the
DIM/BRIGHT Bar. This setting will automatically be saved.
4.
Tap the push pad to change to Mode 2, Set Dim-Lock Level mode.
The locator light will blink twice per second. To change the current Set
Dim-Lock level from 1-100%, use the DIM/BRIGHT Bar. If this feature
is not desired, press and hold the lower half of the DIM/BRIGHT Bar
until no LED is lit. This setting will automatically be saved.
5.
Tap the push pad to change to Mode 3, Set Fade Rate mode. The
locator light will blink 3 times per second. To change the current
Fade Rate, use the DIM/BRIGHT Bar to move the LED to the desired
preset level. This setting will automatically be saved by tapping the
push pad to exit programming mode.
The LED Brightness Display is separated into 7 segments. Each LED
represents a preset level with LED 1 (Preset 1) located at the top and
LED 7 (Preset 7) located at the bottom. Refer to chart for settings and
defaults.
NOTE:
The dimmer will exit program mode after 3 minutes of inactivity.
• Lights Flickering
- Lamp has a bad connection.
- Wires not secured firmly with wire connectors of dimmer or
terminal screws of remote.
• Light does not turn ON and Locator LED does not turn ON
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Neutral not wired to Dimmer (White wire).
• Intermittent dimmer operation
- Minimum load is under 40W.
• Remote does not operate lights
- Ensure that total wire length does not exceed 300 ft.
- Ensure wiring is correct.
• Lights cycle ON and OFF
- Remove excess load.
*
default
** LED #1 is on the top
NOTE:
Dress wires with a bend as shown
in diagram in order to relieve stress when
mounting device
• Position all wires to provide room in
outlet wall box for device.
• Ensure that the word "TOP" is facing
up on device strap.
• Partially screw in mounting screws in
wall box mounting holes
Gently lift
bottom of
push pad out
NOTE:
The locator light will illuminate when the load is in the OFF
position to facilitate access in the dark.
NOTE:
If using the dimmer in a 3-way application, the lights will turn
ON at brightness set on dimmer's DIM/BRIGHT bar. The lighting can
be controlled from either the dimmer or the remote location.
Covered by one or more US & Foreign
Patents and patents pending
Copyright
©
2006 Leviton Manufacturing Co., Inc.
All Rights Including Trade Dress Rights Reserved
Eco-10™ (EcoSeries) is a trademark and Hi-lume
®
is
a registered trademark of Lutron Electronics Inc.
For additional information, contact Leviton’s
Techline at 1-800-824-3005 or visit Leviton's
website at www.leviton.com
OPERATION
4-Way Wiring with Matching
Remote (w/LEDs) Application:
E
Testing your Dimmer prior to mounting
in wall box:
Step 4
Restore Power:
Restore power at circuit breaker or
fuse.
Installation is complete
.
Step 6
TROUBLESHOOTING
FCC COMPLIANCE STATEMENT
3
3
No Fade
Approx. 3s from full on
7
7
Approx. 1.5s from full off
Approx. 10s from full on
6
6
Approx. 1.5s from full off
Approx. 5s from full on
5
5
Approx. 0.5s from full off
Approx. 1.5s from full on
4
4
Approx. 0.5s from full off
Approx. 3s from full on
2
2
No Fade
No Fade
1*
1
Approx. 1.5s from full off
Approx. 3s from full on
Preset
Fade Off
Fade On
LED**
Fade Rate Presets
Advanced Features Summary
Mode
Description
Range
Default
Set Min. Brightness
1 - 50%
25%
1
Set Dim-Lock Level
0
0 -100%, 0=no lock
2
Select Fade Rate
1, 2, 3, 4, 5, 6 or 7
Preset #1
3
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof
of purchase date, and a description of the problem to
Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591.
This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused,
opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions.
There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose
, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness
for a particular purpose, is limited to five years.
Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation
. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
1
2
3
4
5
6
7
LED
Brightness
Display
Push Pad (Default settings)
Turn ON from OFF position:
Tap – Lights turn ON to preset level.
Press and Hold – Lights turn ON to full
bright.
Turn OFF from ON position:
Tap – Lights turn OFF.
DIM/BRIGHT Bar
BRIGHTEN:
Press upper half of DIM/BRIGHT Bar
– Lights brighten to desired level.
DIM:
Press lower half of DIM/BRIGHT Bar –
Lights dim to desired level. If you continue
to hold, the lights will DIM to minimum
level and then turn OFF.
NOTE:
When lights are OFF you can
change the light level that the lights will
turn ON to using the DIM/BRIGHT Bar. If
there is a power outage, when the power
is restored the lights will return to the last
setting before the power interruption.
Push
Pad
Locator
Light
LED
Brightness
Display
DIM/
BRIGHT
Bar
• Restore power at circuit breaker or
fuse.
• Press pad until locator light is OFF.
Lights should turn ON. If lights do not
turn ON, press the upper half of DIM/
BRIGHT bar until the lights brighten.
If lights still do not turn ON, refer to
the TROUBLESHOOTING section.
Green
Ground
Green
Ground
Green
Ground
Dimmer
Black
LOAD
Orange
Orange
120V Hi-Lume
®
or
ECO-10
TM
(EcoSeries)
Ballast
Red
Yellow/
Red
White
WH
BK
YL/RD
YL/RD
Black
White
Matching Remote
(w/LEDs)
Matching Remote
(w/LEDs)
Hot (Black)
Line
120VAC
60Hz
Neutral (White)
WH
BK
Installation may now be completed
by tightening mounting screws into
wall box. Attach wallplate.
Dimmer Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
Step 5
DI-000-VZH06-02C
Matching Remote
Matching Remote
Dimmer
Black
White
Orange
Green
Red
Yellow/Red
BK
YL/RD
WH
Terminal
Screw marked
White (WH)
Terminal
Screw marked
Yellow/Red
(YL/RD)
RD
BK
YL/RD
WH
Terminal
Screw marked
White (WH)
Terminal
Screw marked
Yellow/Red
(YL/RD)
RD
Dimmer
Matching Remote (w/LEDs)
Black
LOAD
Orange
Orange
Hot (Black)
120V Hi-Lume
®
or
ECO-10
TM
(EcoSeries)
Ballast
Line
120VAC
60Hz
Neutral (White)
Red
Yellow/
Red
White
WH
BK
YL/RD
Black
White
Green
Ground
Green
Ground
3-Way with Matching Remote
(w/LEDs) Wiring Application:
D
Matching Remote
Dimmer
Black
White
Orange
Green
Red
Yellow/Red
BK
YL/RD
WH
Terminal
Screw marked
White (WH)
Terminal
Screw marked
Yellow/Red
(YL/RD)
RD