Page 4
Dimmer Equipment Connection
Connecting the MC 7000 Series Lighting Console to Leviton-NSI dimming equipment is very simple.
You need only connect a single 3 conductor audio cable (standard microphone cable equipped with a 3-
pin XLR type connector) to either of the jacks marked MICROPLEX on the rear apron of the console. It
doesn’t matter which jack is used, two jacks are provided for convenience. Connect the other end of the
cable to the Leviton-NSI dimming equipment.
If the console is equipped with the DMX512 option, connection to the dimming equipment is provided
through the 5-pin XLR type connector located on the rear apron of the console. This connector adheres
to the USITT standard on DMX512 and will support up to 32 (16) dimmer channels with one 3-wire
cable. Since remote power is not provided on this connector, the power supply included with the DMX512
option must be used.
OVERVIEW
Front Panel
1. Channel Levels:
These 8 (16) [24] LED’s show the current intensity of each of the console control
channels. The LED’s are inactive whenever the console is in the single scene mode.
2. Scene X:
These 8 (16) [24] slide controls are used to control the intensities of channels 1 -
8 (1 - 16) [1 - 32] . The overall intensity of the scene created is controlled with the
X Crossfader.
3. Scene Y:
These 8 (16) [24] slide controls are used to control the intensities of channels 1 -
8 (1 - 8) [1 - 24], channels 9 - 16 (17 - 32) [25 - 48], or scenes 1 - 8 (1 - 16) [1 - 24]
depending upon the consoles current operating mode. The overall intensity of
the scene created is controlled with the Y Crossfader.
4. Bump Buttons:
These 8 (16) [24] buttons are used to bring an individual or group of channels,
depending upon console operating mode, to full intensity.
5. Program Button:
This button is used to program the Scene Masters, the 2 Chases, and the Flash
Scenes. Programming is active when the Program LED is lit.
1
2
3
4
5
N / C
N / C
Common
DMX Data -
DMX Data +
Female DMX512
XLR Pin Configuration
MPX Data
2
1
3
+15 VDC
Common
Female Microplex
XRL Pin Configuration
MPX Data
1
2
3
Common
+15 vdc
Male Microplex
XRL Pin Configuration