Leviton JCC JC090001 Installation Manual Download Page 1

2.5 Metres

4 Metres

10 Metres

company

a

Installation guide for LED Floodlights

Warnings & Cautions

• 

To avoid electric shock, serious injury or property damage, 
 isolate power before installing, removing or servicing the product.

• 

It is recommended that luminaires are installed by a qualified  

electrician to ensure the installation complies with the local 
current wiring regulations. 

• 

Any broken or damaged parts should be replaced as soon as possible.

• 

JCC will not accept responsibility for claims arising from  
sub-standard installations; which will void the warranty.

• 

These products are designed for connection to a 220-240V~ 50/60Hz.

• 

The light source of this luminaire is not replaceable: When the light source reaches 
the end of it’s life, the whole of the luminaire must be replaced.

• 

It may be necessary to upgrade your MCBs to allow for increased inrush current. 

• 

Terminal block not included. Installation may require advice from a qualified person.

• 

Do not install in areas that are exposed to continual running water or prone  

to flooding. 

• 

Ensure that the mounting surface is both flat and stable.

• 

Never remove the lens cover as this will damage the sensor & render all  
warranties invalid.

INSTALLATION

ENGLISH

• 

 Read instructions and check that you have all of the tools and  

 

accessories required to complete the installation correctly. Isolate 
power supply before starting the installation. 

IP65 PIR LED Floodlights

RoHS

Compliant

IP65

jcc

.co.uk

V7_May_2022_RS

Installation procedure

1.

  Prepare the mains input cable for termination. Note that this  

product is class I and as such must be fitted with an earth connection.

2.

  Drill mounting holes and insert suitable wall plugs. 

3.

  Rotate fitting to access screw mounting points on the bracket  and secure 

using suitable fixings.

4.

    Terminate input wiring to the fitting as per Fig. 1 to the left using a

     suitable IP rated connector.

5. 

 Check seals, gaskets and the cable gland integrity before testing  

the luminaire.

6. 

Turn on power supply and test for correct operation.

The floodlight will light up for 5 seconds, then turn off. It is now in automatic 

PIR detection mode.

Note: The PIR has a manual override function.

To operate the manual override function: 

Turn the power OFF/ON/OFF/ON  within 3 seconds.

To return to Automatic PIR detection mode: 

Turn off power for 5 seconds, then turn power ON. 

If the power is off for longer than 15 seconds the floodlight will light up for 5 

seconds before activating automatic PIR detection mode.

Positioning The Unit (Fig. 2)

When selecting the mounting position take into account the following points:

1. 

The sensor is designed for optimum performance when mounted 2.5 

meters above ground level. 

2. 

Avoid positioning close to trees or shrubs; which may cause false  

triggering during windy weather. 

3. 

Avoid pointing at or positioning close to heat sources such as flu’s of heat 

extraction units; which may cause false triggering. 

4. 

Avoid positioning too close to bright lights, the unit will not function when 

setting LUX level to dark. 

5. 

The sensor is most sensitive to movement across the detection area as 

opposed to directly towards or away from the unit. 

The Field of Detection (Fig. 3)

The field of detection can be adjusted by rotating the PIR both horizontally 

and vertically to avoid any false detections from neighbouring grounds  
or streets.

Operation Mode & Adjusting (Fig. 4)

1. ADJUSTING THE LUX CONTROL LEVEL: The LUX control module has a built 

in sensing device (photocell) that detects daylight and darkness by rotating 
the LUX knob clockwise or anti clockwise/light to dark, you can set unit to 
the desired LUX level. Note:

 Wait for 5 - 10 seconds for the stability of the 

photocell (CDS) when adjusting the LUX level.
2. ADJUSTING THE DURATION TIME: The length of time sensor remains on 
after activation can be adjusted from (3seconds to 8minutes). Rotate the 

TIME knob to increase or decrease the duration time. Note: Once the load 
has been triggered by the PIR detector any subsequent detection will restart 
the time period.

3. ADJUSTING THE DISTANCE: Rotate the SENS knob to increase of decrease 
the distance of which movement will be picked up, from 4-10 metres.

Figure 1. Mains input 

220-240V 50/60Hz / Class I

Live (+)

brown

Earth

yellow/green

Neutral (-)

blue

Available finishes: 

10W/20W/30W Black and 
White, 50W Black only

Terminal block must comply to EN 60998-2-1 or EN 60998-2-2

Wiring colours are for reference only

*Detection distance will vary, 

depending on installation height

Time Delay:
Ambient Light:
Detection Distance*:
Detection Range:
Installation Height:
Standby Power Consumption:

3s to 8 mins 
5lux-2000lux 
4-10m 
120°
2.5m
<0.5W

PIR Specification

Beam angle: 

110°

Fig. 2

Fig. 3

Fig. 4

SENS

LUX

TIME

3s to 8mins

4m to 10m 5 lux to 2000 lux

Total circuit 

wattage

Lumens LpcW Colour 

temp.

Ra

10W

1000

100

 

4000K 70

20W

2100

105

4000K

70

30W

2800

93

4000K

70

50W

4500

90

4000K

70

General Maintenance

JCC recommends that all exterior products, especially those with stainless steel  

components are cleaned with warm water and dried with a chamois leather or  

absorbent dry cloth. Weathering, environmental pollution and bird droppings should be 

cleaned off with a non-abrasive cleaner suitable for the material type. To preserve the 

finish of the product, clean every two to three months. After installation is complete, 

then bi-annually, grease or lubricate removable fixings, to help ensure maintenance is 

trouble free.

120°

PIR

Reviews: