Features and Benefits

General

  

Replaces a single pole switch for control of a ventilation fan 

or a fan/light combination

  

Neutral wire is required for operation

  

Microprocessor control with digital sensing technology

  

Meets CALGREEN and CA Title 24 requirements; sensor is equipped 

with user adjustable humidity range set points to set the minimum 

humidity level at which the fan will automatically operate

  

Automatic ventilation/Air Cycle mode for continuous operation 

with hourly pre-set time outs

  

Green LED functions as a status indicator (Fan ON/OFF, Air Cycle mode, 

Manual Override) 

  

Compatible with Incandescent, LED, CFL and Fluorescent lighting loads

  

Use with existing or new ventilation fans up to 1/6 HP, 3 Amp

  

Screw terminals for easy installation

  

Compatible with Decora

®

 and Decora Plus

TM

 wallplates

  

Available in White, Ivory and Light Almond. Color change kits available

Automatic Fan Control

  

The sensor automatically detects excess humidity and activates 

a ventilation fan for control of excess condensation*

  

Built-in timer sets the “minimum ON time” for the ventilation fan. 

The sensor timer settings can be custom set to 10, 20, 30 or 45 minute 

intervals

  

The sensor will continue to operate the fan for the minimum set time 

or until there is a reduction in room humidity level. This greatly reduces 

the chance of condensation developing

  

Sensitivity level adjustment allows the user to adjust the sensitivity 

level of the sensor to prevent false cycling   

Manual Fan Control

  

The device can be manually turned on by pressing 

the fan icon to address immediate ventilation needs. 

The fan will turn OFF automatically after 10 minutes 

or the set time out 

*  The Leviton Humidity Sensor and Fan Control will not indepen-

dently eliminate condensation. It must be used with a properly 

sized and rated ventilation fan in an enclosed space. 

Ratings

  

120VAC, 60Hz, Single Pole

  

600W Incandescent 

  

150W LED, CFL 

  

1/6 HP, (3A) Fan

  

400VA Inductive, Ballast 

Agency Standards and Compliance

  

cULus

  

Standards UL 873 and C22.2 No. 24

  

File No. E79658

  

CALGREEN and CA Title 24 Compliant

Installation Recommendations for Bath Fan Control

  

It is recommended that in large spaces the IPHS5 Humidity Sensor 

and Fan Control be placed within close proximity to the shower/

tub (steam/vapor source) to most effectively measure/monitor 

for excess humidity

  

Ceiling heights in excess of 8 feet may affect the sensors’ ability 

to properly detect shower/tub steam

  

The sensor requires a closed room to properly operate.  

Opening a door during operation may temporarily interrupt 

the operating cycle

  

Changes in season may affect operation of the sensor due 

to ambient air temperature and humidity. Please review the 

sensor instructions for sensitivity and humidity adjustment 

if required

Summary of Contents for IPHS5-1LW

Page 1: ...n areas of high humidity dampness or rooms prone to condensation and mildew such as Bathrooms Basements Laundry Rooms Home Spas The sensor also helps reduce energy usage by automatically operating the fan only when needed to control excess humidity General Operation Automatic Humidity Control Mode The sensor will automatically turn the fan ON upon detecting excess humidity The sensor will continue...

Page 2: ...umidity level This greatly reduces the chance of condensation developing Sensitivity level adjustment allows the user to adjust the sensitivity level of the sensor to prevent false cycling Manual Fan Control The device can be manually turned on by pressing the fan icon to address immediate ventilation needs The fan will turn OFF automatically after 10 minutes or the set time out The Leviton Humidi...

Page 3: ...Sensor Black White RD Green Ground Line 120 VAC 60Hz 2 3 1 4 20 off Lo Md off Hi cycle 80 Sensitivity Lo Md O f f O f f Hi Time Humidistat 2 3 1 4 20 80 cycle 10 min 45 min 20 min 30 min Stop Mark 1 2 3 1 SENSITIVITY Adjust low medium or high the sensitivity to ambient humidity changes 2 TIME Adjust the minimum ON time of fan 3 HUMIDISTAT Turn ON the air cycle or adjust the humidity set points ...

Page 4: ...Mexico DF Mexico CP 11290 Telephone 52 55 5082 1040 www leviton com mx G 9059 K13 dp Ordering Information Description Rating 120VAC Cat No Color Humidity Sensor Fan Control 600W Incandescent 150W LED CFL 400VA MLV Fluorescent 1 6 HP 3A Fan IPHS5 1LW White Humidity Sensor Fan Control 600W Incandescent 150W LED CFL 400VA MLV Fluorescent 1 6 HP 3A Fan IPHS5 1LI Ivory Humidity Sensor Fan Control 600W ...

Reviews: