PK-93818-10-00-0A
© 2009 Leviton Mfg. Co., Inc.
For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only) www.leviton.com
LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that
this product at the time of its sale by Leviton is free of defects in materials and workmanship under
normal and proper use for two years from the purchase date. Leviton’s only obligation is to correct
such defects by repair or replacement, at its option, if within such two year period the product
is returned prepaid, with proof of purchase date, and a description of the problem to
Leviton
Manufacturing Co., Inc., Att: Quality Assurance Department, 201 North Service Road,
Melville, New York 11747.
This warranty excludes and there is disclaimed liability for labor for
removal of this product or reinstallation. This warranty is void if this product is installed improperly
or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or
is not used under normal operating conditions or not in accordance with any labels or instructions.
There are no other or implied warranties of any kind, including merchantability and fitness
for a particular purpose
, but if any implied warranty is required by the applicable jurisdiction, the
duration of any such implied warranty, including merchantability and fitness for a particular purpose,
is limited to two years.
Leviton is not liable for incidental, indirect, special, or consequential
damages, including without limitation, damage to, or loss of use of, any equipment, lost
sales or profits or delay or failure to perform this warranty obligation
. The remedies provided
herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
FCC COMPLIANCE STATEMENT:
Contains FCC ID: SZV-TCM2XXC. Contains IC: 5713A-TCM2XXC
The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (i.) this device may not cause harmful interference and (ii.) this device must accept
any interference received, including interference that may cause undesired operation.
Leviton is a registered trademark of Leviton Mfg. Co. in the United States, Canada, Mexico, and
other countries. Other trademarks herein are the property of their respective owners.
Press Transmitter
Figure B
Figure C
Clear All
LRN CLR
POWER/RX
8-30 VDC
8-28 VAC
POWER
R1
R2
R3
R4
R5
R6
R7
R8
NO1
NO2
C1&2
NO3
NO4
C3&4
NO5
NO6
C5&6
NO7
NO8
C7&8
LVRX-8 Low Voltage Relay Receiver
8 Channels • SPST
Form A • 2A resistive
Figure D
4 Channel Basic Wiring Diagram
RELAY COMMON TERMINALS:
FORM-C RELAYS:
THERE ARE FOUR RELAYS IN THE DEVICE. EACH RELAY HAS THREE TERMINALS AVAILABLE FOR EXTERNAL CONNECTIONS: COMMON,
NORMALLY OPEN, AND NORMALLY CLOSED.
EACH OF THE FOUR RELAYS HAS A COMMON TERMINAL. THE COMMON TERMINALS ARE NOT CONNECTED TO EACH OTHER INSIDE THE DEVICE.
IN THE EXAMPLE SHOWN, THE COMMON TERMINALS ARE EXTERNALLY CONNECTED TO THE POSITIVE SUPPLY VOLTAGE. HOWEVER, THE COMMON
TERMINALS CAN BE CONNECTED TO ANY VOLTAGE WITHIN THE SPECIFICATIONS OF THE RELAY TERMINALS. SEE DATASHEET.
WIRELESS CONTROL
SIGNAL UP TO 150 FT.
LINE OF SIGHT
ANY 8-28VAC OR 8-30VDC
POWER ADAPTER
(SOLD SEPARATELY)
ANY LOW VOLTAGE
LOAD (FLASHLIGHT
BULBS SHOWN).
LD-4C
LD-3C
LD-2C
LD-1C
8-30VDC
8-28VAC
POWER
+ -
NO1 C1 NC1
LVRX-4
NO2 C2 NC2 NO3 C3 NC3 NO4 C4 NC4
R1
R2
R2
R2
LD-4O
LD-3O
LD-2O
LD-1O
WSS0S-D0x
BATTERY-FREE,
WIRELESS SWITCHES
WSS0S-D2x
LOADS CONNECTED
TO THE NORMALLY
CLOSED CONTACTS
WILL BE TURNED
ON UNTIL A
WIRELESS SWITCH
ACTIVATES THEIR
RESPECTIVE
CHANNEL. HERE,
LOAD LD-2C IS OFF,
BECAUSE CHANNEL
2 HAS BEEN
ACTIVED BY ONE OF
THE WIRELESS
SWITCHES.
TO THE NORMALLY
OPEN CONTACTS
WILL BE TURNED
OFF UNTIL A
WIRELESS SWITCH
ACTIVATES THEIR
RESPECTIVE
CHANNEL. HERE,
LOAD LD-2O IS ON,
BECAUSE CHANNEL
2 HAS BEEN
ACTIVED BY ONE OF
THE WIRELESS
SWITCHES.
WSPAS LV-4
Enter Learn Mode
Figure A
LRN CLR
POWER/RX
8-30 VDC
8-28 VAC
POWER
R1
R2
R3
R4
R5
R6
R7
R8
NO1
NO2
C1&2
NO3
NO4
C3&4
NO5
NO6
C5&6
NO7
NO8
C7&8
LVRX-8 Low Voltage Relay Receiver
8 Channels • SPST
Form A • 2A resistive
Figure E
8 Channel Basic Wiring Diagram
RELAY COMMON TERMINALS:
FORM-A RELAYS:
THERE ARE EIGHT RELAYS IN THE DEVICE. EACH RELAY HAS TWO TERMINALS AVAILABLE FOR EXTERNAL CONNECTIONS: COMMON
AND NORMALLY OPEN.
EACH OF THE EIGHT RELAYS HAS A COMMON TERMINAL. THE COMMON TERMINALS OF FOUR PAIRS OF RELAYS ARE TIED TOGETHER, INTERNALLY,
AS SHOWN ON THE WIRING TERMINAL LABEL. IN THE EXAMPLE SHOWN, THE COMMON TERMINALS ARE EXTERNALLY CONNECTED TO THE POSITIVE
SUPPLY VOLTAGE. HOWEVER, THE COMMON TERMINALS CAN BE CONNECTED TO ANY VOLTAGE WITHIN THE SPECIFICATIONS OF THE RELAY
TERMINALS. SEE DATASHEET.
WIRELESS CONTROL SIGNAL
UP TO 150 FT. LINE OF SIGHT
ANY 8-28VAC OR 8-30VDC
POWER ADAPTER
(SOLD SEPARATELY)
LVRX-8
WSS0S-D0x
BATTERY-FREE,
WIRELESS SWITCHES
WSS0S-D2x
LOADS CONNECTED
TO THE NORMALLY
OPEN CONTACTS
WILL BE TURNED
OFF UNTIL A
WIRELESS SWITCH
ACTIVATES THEIR
RESPECTIVE
CHANNEL. HERE,
LOAD LD-3O IS ON,
BECAUSE CHANNEL
3 HAS BEEN
ACTIVED BY ONE OF
THE WIRELESS
SWITCHES.
LD-1O
LD-3O
LD-7O
LD-5O
ANY LOW
VOLTAGE
LOAD
(FLASHLIGHT
BULBS
SHOWN).
LD-6O
LD-4O
LD-2O
LD-8O
R1
NO1 C1&2 NO2
8-30VDC
8-28VAC
POWER
+ -
R7
R5
R3
WSPAS LV-8
NO3 C3&4 NO4 NO5 C5&6 NO6 NO7 C7&8 NO8
R2
R4
R6
R8
BATTERY-FREE,
WIRELESS SWITCHES
BREAKER PANEL
BLACK
CONTROL ON
BLUE
RED
COMMON
+24VDC
MOTOR
OSP20-000
CONTROL ON
COMMON
BLUE
BLACK
RED
+24VDC
T3
RELAY CONTACT BLUE
RELAY CONTACT BLUE
AC POWER 240V WHITE
AC POWER 240V BLACK
T1
T2
OL
OL
OL
L1
L2
L3
START
COIL
STOP
RELAY CONTACT BLUE
RELAY CONTACT BLUE
AC POWER 240V WHITE
AC POWER 240V BLACK
STOP
START
R1 R2 R3 R4
RELAY CHANNELS PROGRAMMED IN MOMENTARY MODE
R1 PROGRAMMED TO RESPOND TO TOP OF ROCKER (START)
R2 PROGRAMMED TO RESPOND TO BOTTOM OF ROCKER (STOP)
OSP20-000
240V PHASE-TO-PHASE VOLTAGE
240V PHASE-TO-PHASE VOLTAGE
MOTOR STOPS BY PRESSING STOP SWITCH OR BY PRESSING THE BOTTOM HALF OF ROCKER ON ANY WIRELESS SWITCH.
CAUTION! IT IS POSSIBLE FOR WIRELESS LINK TO FAIL DUE TO INTERFERENCE OR OTHER REASONS.
DO NOT RELY ON WIRELESS LINK FOR EMERGENCY START/STOP APPLICATIONS OR WHEN THE RISK
OF PERSONAL INJURY, OR DEATH MAY RESULT DUE TO WIRELESS LINK FAILURE.
MOTOR STARTS BY PRESSING START SWITCH OR BY PRESSING THE TOP HALF OF ROCKER ON ANY WIRELESS SWITCH.
Figure F
Wireless Control of Existing Motor Start Switch
R2
R1
N.O.