FEATURES
• Leviton's Decora
®
Style design
• Scene Capabilities
• Soft fade ON/OFF
• Power interruption - load returns to existing state
• Minimum Brightness Adjustment
• ON/OFF LED indicates status of load
• Brightness Level Display
• Color conversion available
• Double Tap functions
FCC COMPLIANCE STATEMENT
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
This device must not cause harmful interference, and (2) This device must accept any interference received,
including interference that may cause undesired operation.
INSTALLATION INSTRUCTIONS
WARNING:
TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL
CODES AND REGULATIONS.
WARNING:
IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A
QUALIFIED ELECTRICIAN.
WARNING:
TO REDUCE THE RISK OF OVERHEATING AND POSSIBLE DAMAGE TO THIS DEVICE AND
OTHER EQUIPMENT, USE ONLY WITH THE APPROPRIATE ADVANCE MARK X™ 120V ELECTRONIC
DIMMING BALLASTS FOR CONTROLLING THE SPECIFIC FLUORESCENT LAMPS.
OTHER CAUTIONS:
1.
BOTH LIGHTING FIXTURE AND DIMMER MUST BE
GROUNDED
.
2.
DISCONNECT POWER WHEN SERVICING OR CHANGING LAMPS.
3.
USE THIS DEVICE ONLY WITH COPPER OR COPPER CLAD WIRE. WITH ALUMINUM WIRE USE ONLY
DEVICES MARKED CO/ALR OR CU/AL.
MULTI-GANG INSTALLATION:
When ganging dimmers, the side sections of the mounting strap must be removed. Use pliers to carefully bend
side sections back and forth until they break off
(refer to Figure 1)
. The side sections dissipate heat, so removing
them requires a derating of the dimmer's capacity
(refer to chart)
.
MAXIMUM BULB WATTAGE:
Advance Mark X™ dimmers are rated in Volt-Amps (VA). The maximum bulb wattage is determined by the efficiency
of the Advance Mark X™ ballast.
Table 1
shows the maximum number of ballasts that can be connected to a
single dimmer for different Advance Mark X™ ballasts. Also note the table shows maximum ballasts for multi-
gang installations.
NOTE:
For multiple ballasts on one dimmer, use only the same model ballast.
TO INSTALL:
1.
WARNING:
TO AVOID FIRE, SHOCK, OR DEATH;
TURN OFF POWER
AT CIRCUIT BREAKER OR FUSE
AND TEST THAT POWER IS OFF BEFORE WIRING!
2.
Remove existing wallplate and switch or dimmer, if applicable.
3.
Remove 3/4" (1.9 cm) of insulation from each circuit conductor. Make sure that ends of conductors are straight.
4.
Connect lead wires per appropriate WIRING DIAGRAM as follows: Twist strands of each lead tightly and,
with circuit conductors, push firmly into appropriate wire connector
(see chart for allowable wire
connector and number of conductor combinations)
. Screw connectors on clockwise making sure that no
bare conductor shows below the wire connectors. Secure each connector with electrical tape.
5.
Carefully position all wires to provide room in outlet box for dimmer. Mount dimmer into box with mounting
screws supplied.
6.
Restore power at circuit breaker or fuse. Turn the dimmer ON by pressing the upper half of the rocker. The
GREEN LED will turn OFF to indicate power to the dimmer (when the dimmer is OFF, the LED is ON).
NOTE:
This model incorporates a trim adjustment which will allow the installer to precisely set the low end of the
dimming range to suit each installation. This adjustment is preset at the factory and should require no further
adjustments for most installations. If adjustment is required proceed as follows, otherwise continue with step 9:
7.
The brightness adjustment is located on the side of the dimmer
(refer to Figure 1)
. Using a small, insulated
screwdriver, depress the brightness adjustment switch. To increase the minimum brightness, press the upper
half of the rocker.
To decrease the minimum brightness, press the lower half of the rocker.
8.
Release the rocker. Release adjustment switch and minimum brightness is set. Check for
proper operation by tapping the lower half of the rocker so the lights turn OFF, then
tapping the upper half of the rocker so the lights turn ON.
The lights will turn ON to the new minimum brightness set. If operation is not satisfactory,
repeat step 7.
9.
Attach Decora
®
wallplate (not included).
INSTALLATION IS COMPLETE.
NOTE:
On the lower left corner of the switch frame, there is an air-gap switch. When
servicing a controlled fixture, pull lever out (OFF position). This will cut the power to the
fixture. After servicing is complete, push the lever in (ON position) to restore power. The lever
must be pushed in all the way (ON position) for normal operation.
DI-00X-MCX10-00A
Scene Capable Dimmer
120VAC, 60Hz
Fluorescent Only
Cat. No. MCX1Ø-1, 1000VA
(w/brightness level display)
Total minimum wattage
must exceed 60VA
For use w/ Advance
Mark X™ Dimming Ballasts
INSTALLATION INSTRUCTIONS
DI-00X-MCX10-00A
C O L L E C T I O N B Y L E V I T O N
Upper
Rocker
Air Gap
Switch
ON/OFF
LED
Lower
Rocker
Minimum Brightness
Adjustment Switch
Brightness Level
Display
Mounting Strap
Side Sections
Figure 1 – Dimmer Functions
For Technical Assistance Call:
1-800-824-3005 (U.S.A. Only)
1 800 405-5320 (Canada Only)
www.leviton.com
LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not
for the benefit of anyone else that this product at the time of its
sale by Leviton is free of defects in materials and workmanship
under normal and proper use for two years from the purchase
date. Leviton’s only obligation is to correct such defects by repair
or replacement, at its option, if within such two year period the
product is returned prepaid, with proof of purchase date, and a
description of the problem to
Leviton Manufacturing Co., Inc.,
Att: Quality Assurance Department, 59-25 Little Neck
Parkway, Little Neck, New York 11362-2591 (In Canada send
to Leviton Mfg. of Canada Ltd., 165 Hymus Blvd., Point
Claire, (Quebec), Canada H9R 1E9).
This warranty excludes
and there is disclaimed liability for labor for removal of this product
or reinstallation. This warranty is void if this product is installed
improperly or in an improper environment, overloaded, misused,
opened, abused, or altered in any manner, or is not used under
normal operating conditions or not in accordance with any labels
or instructions. There are no other or implied warranties of any
kind, including merchantability and fitness for a particular
purpose, but if any implied warranty is required by the applicable
jurisdiction, the duration of any such implied warranty, including
merchantability and fitness for a particular purpose, is limited to
two years. Leviton is not liable for incidental, indirect, special, or
consequential damages, including without limitation, damage
to, or loss of use of, any equipment, lost sales or profits or delay
or failure to perform this warranty obligation. The remedies
provided herein are the exclusive remedies under this warranty,
whether based on contract, tort or otherwise.
Two More than
Cat. No. Single Gang
2 Gang
MCX1Ø-1 1000VA 800VA 700VA
MAXIMUM LOAD PER DIMMER FOR MULTI-GANG
CFM26W/GX24Q
CFM32W/GX24Q
CFM42W/GX24Q
CFQ26W/G24Q
F25T8
F25T8
F25T8
F32T8
F32T8
F32T8
FT40W/2G11
FT40W/2G11
REZ-1T32
REZ-1T32
REZ-1T42
REZ-2Q26
REZ-132
REZ-2S32
REZ-3S32
REZ-132
REZ-2S32
REZ-3S32
REZ-1TTS40
REZ-2TTS40
Advance
Mark X™
Part No.
Lamps
Max. # Ballasts/Dimmer for Multi-gang
Two
Ganged
32
26
20
17
32
17
11
28
14
9
25
12
26
21
16
14
26
13
9
22
11
8
20
10
More than
2 Gang
22
18
14
12
22
12
8
19
10
7
17
9
Single
Gang
TABLE 1
Cat. No. MCX1Ø-1, 120V – For use with
Advance Mark X™ 120V Dimming Ballasts
WIRE CONNECTOR / # OF CONDUCTOR COMBINATION CHART
1- #12 w/ 1 to 3 #14, #16 or #18
2- #12 w/ 1 #14 w/ 1 #16 or #18
2- #12 w/ 1 #16 w/ 1 or 2 #18
2- #14 w/ 1 to 3 #16, #18 or #20
4- #16 w/ 1 or 2 #18, #20 or #22
1- #14 w/ 1 to 4 #16, #18 or #20
2- #14 w/ 1 to 3 #16, #18 or #20
2- #14 w/ 1 #16 w/ 1 or 2 #18 or #20
3- #14 w/ 1 or 2 #18 or #20
4- #14 w/ 1 #16 or #18
2- #16 w/ 1 #18 w/ 1 or 2 #20 or #22
1- #14 w/ 1 #18 w/ 1 to 3 #20
3- #14 w/ 1 #16 w/ 1 #18, #20, #22
3- #14 w/ 1 #18 w/ 1 #20 or #22
DI-00X-MCX10-00A
10/4/02, 10:28 AM
1