background image

FEATURES

• Leviton's Decora

® 

Style design

• Scene Capabilities

• Soft fade ON/OFF

• Power interruption - load returns to existing state

• Minimum Brightness Adjustment

• ON/OFF LED indicates status of load

• Brightness Level Display

• Color conversion available

• Double Tap functions

FCC COMPLIANCE STATEMENT

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
This device must not cause harmful interference, and (2) This device must accept any interference received,
including interference that may cause undesired operation.

INSTALLATION INSTRUCTIONS

WARNING:

 

TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL

CODES AND REGULATIONS.

WARNING:

 

IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A

QUALIFIED ELECTRICIAN.

WARNING:

 

TO REDUCE THE RISK OF OVERHEATING AND POSSIBLE DAMAGE TO THIS DEVICE AND

OTHER EQUIPMENT, USE ONLY WITH THE APPROPRIATE ADVANCE MARK X™ 120V ELECTRONIC
DIMMING BALLASTS FOR CONTROLLING THE SPECIFIC FLUORESCENT LAMPS.

OTHER CAUTIONS:

1.

BOTH LIGHTING FIXTURE AND DIMMER MUST BE 

GROUNDED

.

2.

DISCONNECT POWER WHEN SERVICING OR CHANGING LAMPS.

3.

USE THIS DEVICE ONLY WITH COPPER OR COPPER CLAD WIRE. WITH ALUMINUM WIRE USE ONLY
DEVICES MARKED CO/ALR OR CU/AL.

MULTI-GANG INSTALLATION:

When ganging dimmers, the side sections of the mounting strap must be removed. Use pliers to carefully bend
side sections back and forth until they break off 

(refer to Figure 1)

. The side sections dissipate heat, so removing

them requires a derating of the dimmer's capacity 

(refer to chart)

.

MAXIMUM BULB WATTAGE:

Advance Mark X™ dimmers are rated in Volt-Amps (VA). The maximum bulb wattage is determined by the efficiency
of the Advance Mark X™ ballast. 

Table 1 

shows the maximum number of ballasts that can be connected to a

single dimmer for different Advance Mark X™ ballasts. Also note the table shows maximum ballasts for multi-
gang installations.

NOTE:

 For multiple ballasts on one dimmer, use only the same model ballast.

TO INSTALL:

1.

WARNING:

 

TO AVOID FIRE, SHOCK, OR DEATH; 

TURN OFF POWER

 AT CIRCUIT BREAKER OR FUSE

AND TEST THAT POWER IS OFF BEFORE WIRING!

2.

Remove existing wallplate and switch or dimmer, if applicable.

3.

Remove 3/4" (1.9 cm) of insulation from each circuit conductor. Make sure that ends of conductors are straight.

4.

Connect lead wires per appropriate WIRING DIAGRAM as follows: Twist strands of each lead tightly and,
with circuit conductors, push firmly into appropriate wire connector 

(see chart for  allowable wire

connector and number of conductor combinations)

. Screw connectors on clockwise making sure that no

bare conductor shows below the wire connectors. Secure each connector with electrical tape.

5.

Carefully position all wires to provide room in outlet box for dimmer. Mount dimmer into box with mounting
screws supplied.

6.

Restore power at circuit breaker or fuse. Turn the dimmer ON by pressing the upper half of the rocker. The
GREEN LED will turn OFF to indicate power to the dimmer (when the dimmer is OFF, the LED is ON).

NOTE:

 This model incorporates a trim adjustment which will allow the installer to precisely set the low end of the

dimming range to suit each installation. This adjustment is preset at the factory and should require no further
adjustments for most installations. If adjustment is required proceed as follows, otherwise continue with step 9:

7.

The brightness adjustment is located on the side of the dimmer 

(refer to Figure 1)

. Using a small, insulated

screwdriver, depress the brightness adjustment switch. To increase the minimum brightness, press the upper
half of the rocker.
To decrease the minimum brightness, press the lower half of the rocker.

8.

Release the rocker. Release adjustment switch and minimum brightness is set. Check for
proper operation by tapping the lower half of the rocker so the lights turn OFF, then
tapping the upper half of the rocker so the lights turn ON.
The lights will turn ON to the new minimum brightness set. If operation is not satisfactory,
repeat step 7.

9.

Attach Decora

®

 wallplate (not included). 

INSTALLATION IS COMPLETE.

NOTE:

 On the lower left corner of the switch frame, there is an air-gap switch. When

servicing a controlled fixture, pull lever out (OFF position). This will cut the power to the
fixture. After servicing is complete, push the lever in (ON position) to restore power. The lever
must be pushed in all the way (ON position) for normal operation.

DI-00X-MCX10-00A

              

Scene Capable Dimmer

120VAC, 60Hz

Fluorescent Only

Cat. No. MCX1Ø-1, 1000VA

(w/brightness level display)

Total minimum wattage

must exceed 60VA

For use w/ Advance

Mark X™ Dimming Ballasts

INSTALLATION INSTRUCTIONS

DI-00X-MCX10-00A

C O L L E C T I O N  B Y  L E V I T O N

Upper

Rocker

Air Gap

Switch

ON/OFF

LED

Lower

Rocker

Minimum Brightness 

Adjustment Switch

Brightness Level

Display

Mounting Strap

Side Sections

Figure 1 – Dimmer Functions

For Technical Assistance Call:

1-800-824-3005 (U.S.A. Only)

1 800 405-5320 (Canada Only)

www.leviton.com

LIMITED 2 YEAR WARRANTY AND EXCLUSIONS

Leviton warrants to the original consumer purchaser and not
for the benefit of anyone else that this product at the time of its
sale by Leviton is free of defects in materials and workmanship
under normal and proper use for two years from the purchase
date. Leviton’s only obligation is to correct such defects by repair
or replacement, at its option, if within such two year period the
product is returned prepaid, with proof of purchase date, and a
description of the problem to 

Leviton Manufacturing Co., Inc.,

Att: Quality Assurance Department, 59-25 Little Neck
Parkway, Little Neck, New York 11362-2591 (In Canada send
to Leviton Mfg. of Canada Ltd., 165 Hymus Blvd., Point
Claire, (Quebec), Canada H9R 1E9).

 This warranty excludes

and there is disclaimed liability for labor for removal of this product
or reinstallation. This warranty is void if this product is installed
improperly or in an improper environment, overloaded, misused,
opened, abused, or altered in any manner, or is not used under
normal operating conditions or not in accordance with any labels
or instructions. There are no other or implied warranties of any
kind, including merchantability and fitness for a particular
purpose, but if any implied warranty is required by the applicable
jurisdiction, the duration of any such implied warranty, including
merchantability and fitness for a particular purpose, is limited to
two years. Leviton is not liable for incidental, indirect, special, or
consequential damages, including without limitation, damage
to, or loss of use of, any equipment, lost sales or profits or delay
or failure to perform this warranty obligation. The remedies
provided herein are the exclusive remedies under this warranty,
whether based on contract, tort or otherwise.

      

 Two     More than

        Cat. No.           Single      Gang

 

     2 Gang

   

    MCX1Ø-1         1000VA     800VA       700VA

MAXIMUM LOAD PER DIMMER FOR MULTI-GANG

CFM26W/GX24Q

CFM32W/GX24Q

CFM42W/GX24Q

CFQ26W/G24Q

F25T8

F25T8

F25T8

F32T8

F32T8

F32T8

FT40W/2G11

FT40W/2G11

REZ-1T32

REZ-1T32

REZ-1T42

REZ-2Q26

REZ-132

REZ-2S32

REZ-3S32

REZ-132

REZ-2S32

REZ-3S32

REZ-1TTS40

REZ-2TTS40

Advance
Mark X™
 Part No.

Lamps

Max. # Ballasts/Dimmer for Multi-gang

Two

Ganged

32

26

20

17

32

17

11

28

14

9

25

12

26

21

16

14

26

13

9

22

11

8

20

10

More than

2 Gang

22

18

14

12

22

12

8

19

10

7

17

9

Single

Gang

TABLE 1

Cat. No. MCX1Ø-1, 120V – For use with

Advance Mark X™ 120V Dimming Ballasts

WIRE CONNECTOR / # OF CONDUCTOR COMBINATION CHART

1- #12 w/ 1 to 3 #14, #16 or #18
2- #12 w/ 1 #14 w/ 1 #16 or #18
2- #12 w/ 1 #16 w/ 1 or 2 #18
2- #14 w/ 1 to 3 #16, #18 or #20
4- #16 w/ 1 or 2 #18, #20 or #22
1- #14 w/ 1 to 4 #16, #18 or #20
2- #14 w/ 1 to 3 #16, #18 or #20

2- #14 w/ 1 #16 w/ 1 or 2 #18 or #20
3- #14 w/ 1 or 2 #18 or #20
4- #14 w/ 1 #16 or #18
2- #16 w/ 1 #18 w/ 1 or 2 #20 or #22
1- #14 w/ 1 #18 w/ 1 to 3 #20
3- #14 w/ 1 #16 w/ 1 #18, #20, #22
3- #14 w/ 1 #18 w/ 1 #20 or #22