Leviton decora IPV05 Installation Instructions Download Page 2

 

LIMITED 5 YEAR WARRANTY AND EXCLUSIONS

Leviton warrants to the original consumer purchaser and not for the benefit of anyone 

else that this product at the time of its sale by Leviton is free of defects in materials 

and  workmanship  under  normal  and  proper  use  for  five  years  from  the  purchase 

date. Leviton’s only obligation is to correct such defects by repair or replacement, at 

its option, if within such five year period the product is returned prepaid, with proof 

of purchase date, and a description of the problem to 

Leviton Manufacturing Co., 

Inc., Att: Quality Assurance Department, 201 North Service Road, Melville, 

New York  11747. This  warranty  excludes  and  there  is  disclaimed  liability  for  labor 

for  removal  of  this  product  or  reinstallation. This  warranty  is  void  if  this  product  is 

installed  improperly  or  in  an  improper  environment,  overloaded,  misused,  opened, 

abused, or altered in any manner, or is not used under normal operating conditions 

or not in accordance with any labels or instructions. 

There are no other or implied 

warranties of any kind, including merchantability and fitness for a particular 

purpose,  but  if  any  implied  warranty  is  required  by  the  applicable  jurisdiction,  the 

duration  of  any  such  implied  warranty,  including  merchantability  and  fitness  for  a 

particular  purpose,  is  limited  to  five  years. 

Leviton is not liable for incidental, 

indirect, special, or consequential damages, including without limitation, 

damage to, or loss of use of, any equipment, lost sales or profits or delay or 

failure to perform this warranty obligation. The remedies provided herein are the 

exclusive remedies under this warranty, whether based on contract, tort or otherwise.

PK-93917-10-00-2A

   Position all wires to provide room in 

outlet wall box for device.

•   Ensure that the word "TOP" is 

facing up on device strap.

•   Partially screw in mounting screws 

in wall box mounting holes.

•  Restore power at circuit breaker or fuse.

•  Wait 20 seconds for sensor to power up.

•  For IPS05, lights will automatically turn ON  

after power is applied.

•  For IPV05, 

press push pad. Lights should  

turn ON.

 

If lights still do not turn ON, refer to the 

TROUBLESHOOTING section.

 Step 5

Restore Power:

 Restore power at circuit breaker or 

fuse. 

Installation is complete.

 Step 7

Device Mounting:

TURN OFF POWER AT CIRCUIT 

BREAKER OR FUSE.

 Step 6

Installation may now be 

completed by tightening 

mounting screws into wall 

box. Attach wallplate.

 OPERATION

NOTE: Dress wires with a bend as 

shown in diagram in order to relieve 

stress when mounting device.

For additional information, contact Leviton’s Techline at  

1-800-824-3005 or visit Leviton’s website at www.leviton.com

This product is covered by U.S. Pat. No. 7,924,155 & corresponding foreign patents.

© 2012 Leviton Manufacturing Co., Inc.

All Rights Including Trade Dress Rights Reserved

 ADJUSTMENT SETTINGS

 

TROUBLESHOOTING

Lights do not operate with push pad and LED indicator does not 

blink when motion is present:
•   Ensure proper ground connection is present in the wallbox.  

When confirmed, verify wiring connections to sensor.

Lights do not switch ON when motion is detected (IPS05):
•  Motion is beyond sensing range, move closer to switch.

•   Adjust the light level adjustment toward lighter (counterclockwise), 

depending on room conditions.

Lights always stay ON:
•   Check time delay settings and compare to how long the lights stay ON.

•  Ensure that no motion occurs in coverage area for time selected.

•   Check that switch is not installed near a heat source (e.g., stove, lights, 

heat vents) or detecting motion from an adjacent area (e.g., hallway 

traffic). If so, switch may have to be relocated.

Lights do not turn ON - IPV05:
•  Check that control is installed correctly.

•  Check that power is ON.

•  Check that light bulb is functioning.

NOTE: If problems continue, consult an electrician.

IPS05
Auto On: 
Lights will automatically turn ON when 

room is occupied or motion is detected. 

The IPS05 will switch lights OFF when no 

motion is detected in un-occupied room after set 

period of time.
Time delay adjustment: Refer to section on 

Adjustment settings.
The IPS05 will manually turn-on lights or the 

load by depressing the ON/OFF paddle on the 

device. The IPS05 can be set to only turn ON by 

the pushpad (no automatic ON operation) by adjusting the ambient light 

control to the "0" position.
IPV05

Manual On: The IPV05 requires the user to manually turn-on lights or the 

load by depressing the ON/OFF paddle on the device.

The lights or load will automatically turn-off when the room is left  

un-occupied for a set period of time.

Time delay adjustment: Refer to section on Adjustment settings.
Locator Light LED:
LED blinks once every 2 seconds when motion is detected and if the load 

is ON or OFF.

FCC COMPLIANCE STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to following 

two conditions: (1) this device may not cause harmful interference, and (2) this 

device must accept any interference received, including interference that may cause 

undesired operation of the device.
This equipment has been tested and found to comply with the limits for a Class B 

Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to 

provide reasonable protection against harmful interference in a residential installation. 

This equipment generates, uses, and can radiate radio frequency energy and, if not 

installed and used in accordance with the instructions, may cause harmful interference 

to radio communications. However, there is no guarantee that interference will not 

occur in a particular installation. If this equipment does cause harmful interference to 

radio or television reception, which can be determined by turning the equipment OFF 

and ON, the user is encouraged to try to correct the interference by one or more of the 

following measures:
•  Reorient or relocate the receiving Antenna.

•   Increase the separation between the equipment and the receiver.

•   Connect the equipment into an outlet on a circuit different from that to which the 

receiver is connected.

•   Consult the dealer or an experienced radio/tv technician for help.
FCC CAUTION
Any changes or modifications not expressly approved by Leviton Manufacturing Co., 

Inc., could void the user's authority to operate the equipment.

 SENSING AREA COVERAGE

Field-of-View (Horizontal)

Side (Vertical) Field-of-View

Testing your Device prior to mounting in  

wall box:

1.  With power restored and wallplate removed, remove face of device to 

expose setting controls, see color change instructions in page 1. Use 

your finger or a small screwdriver to adjust the light sensitivity and time 

settings on the device as follows:

Light Level Adjustment: 

•  Turn the control clockwise. Lights will turn ON in lighter conditions.
•   Turn the control counter clockwise. Lights will turn ON in less lighting 

conditions.

Time Selection: 

•   Adjust the time selector to the desired length of time the lights are to 

remain ON. Lights will remain ON from 30 seconds to 30 minutes after 

the room is vacated.

•  Turn the control clockwise . Lights will remain ON up to 30 minutes.
•   Turn the control counter clockwise. Lights will remain ON up to 30 

seconds.

2.  Test that the light level and time selection are as desired. If not, repeat 

adjustments until satisfied.

3.  Mount wallplate. INSTALLATION IS COMPLETE.

Lens

Push 

Pad

Locator 

Light

1.5m

5ft

30ft

9.1m

30ft

9.1m

6ft

1.7m

1.8m

6ft

5ft

1.5m

30ft

9.1m

1.4m

4ft

8.4m

27ft

2.1m

7ft

1.5m

5ft

1.2m

4ft

1.7m

6ft

2.6m

8ft

Light Level 

Adjustment

Time 

Selection

1    2
0    3

1    2
0    3

0
1
2
3

Settings

30 Sec

5 Min

15 Min
30 Min

Time

Reviews: