LIMITED 2 YEAR WARRANTY AND EXCLUSIONS

Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for two years from the purchase date. Leviton’s only obligation is to correct such
defects by repair or replacement, at its option, if within such two year period the product is returned prepaid, with proof of purchase date, and a description of the problem to 

Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York

11362-2591.

 This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under

normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied
warranty, including merchantability and fitness for a particular purpose, is limited to two years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this
warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.

Connect wires per WIRING DIAGRAM as follows:

Screw wire nuts on clockwise making sure no bare
conductors show below the wire connectors. Secure each
connector with electrical tape.

NOTE:

 Dimmer can be installed on either the Load or Line

side.

Green dimmer Ground lead to Green or bare copper wire
in wall box.

Black dimmer lead to tagged (common) wall box wire
identified when removing old switch.

Remove Red insulating label from Red lead.

Any Red dimmer lead to any of the remaining
wall box wires.

Remaining Red dimmer lead to remaining wall box wire.

Testing your Dimmer prior to mounting in wall
box:

Dimmer Mounting:

TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.

Restore Power:

 Restore power at circuit breaker or

fuse. 

Installation is complete.

OPERATION

NOTE:

 If using the dimmer in a 3-way application, the lights will

turn ON at brightness set on dimmer's slide control lever. The
lighting level can be controlled from either the dimmer or the
switch location.

Step 7

PK-92950-10-00-2D

Step 5b

Hot (Black)

Neutral (White)

Dimmer

3-Way Switch

Red

Black

Green

Ground

Green

Ground

Black

White

Red

Line 

120/277VAC, 60Hz

Common

Terminal

(Black Screw)

Ballast

Red

Blue

Yellow

To Lamps

Primary

Side

Step 6

Step 5a

Black

Red

Neutral

Green

Ground

Red

This wire is used in 3-way installations only.
For single pole installations, do not remove this
insulating label.

Black

Tag

Red

Green

Red

Neutral

Ground

Step 5b
con’t

Restore power at circuit breaker or
fuse.

Carefully holding Dimmer as
shown, move slider control lever to
highest position. Lights should turn
ON to brightest level. If lights do not
turn ON, depress push-button switch
once. Lights should turn ON to
brightest level.

If lights still do not turn ON, refer
to the TROUBLESHOOTING
section.

Installation may now be completed
by carefully positioning
all wires to provide room in wall box
for dimmer. Mount dimmer
into box with mounting screws
supplied. Attach wallplate.

ON/OFF:

Depress push-button switch to ON
position - Lights will turn ON.

Depress push-button switch to OFF
position - Lights will turn OFF.

BRIGHTEN & DIM:

Move slider control lever - Lights will
BRIGHTEN or DIM.

Insert wires

straight then twist

clockwise

Insert wires

straight then twist

clockwise

Electrical

Tape

Electrical

Tape

Step 8

Hot (Black)

Neutral (White)

Dimmer

Black

Green

Ground

Black

White

Red

Line 

120/277VAC, 60Hz

Red

Insulating

Label

Ballast

Red

Blue

Yellow

To Lamps

Primary

Side

Single-Pole Wiring Application:

Connect wires per WIRING DIAGRAM as follows:

Screw wire nuts on clockwise making sure no bare
conductors show below the wire connectors. Secure each
connector with electrical tape.

NOTE:

 Dimmer can be installed on either the Load or Line

side.

Green dimmer Ground lead to Green or bare copper
wire in wall box.

Black dimmer lead to any wall box wire removed
from old switch.

Red dimmer lead without insulating label to remaining
wall box wire. 

Proceed to Step 6.

Remaining Red dimmer lead should have Red insulation
label affixed. 

Proceed to Step 6.

NOTE: 

If insulating label is not affixed to Red lead, use a

small wire nut or electrical tape to cap off. 

Proceed to Step 6.

3-Way Wiring  Application:

TROUBLESHOOTING

Lights Flickering
- Lamp has a bad connection.
- Wires not secured firmly with
  wire connectors.

Light does not turn ON and
ON/OFF LED does not turn ON
- Circuit breaker or fuse has
  tripped.
- Lamp is burned out.
- Sockets are not Rapid Start type.
- Lamp Neutral connection is not wired.

NOTE: If further information is needed in identifying the HOT wire
in a 3-Way application, go to 

Leviton's website at www.leviton.com.

CFM26W/GX24Q

CFM32W/GX24Q

CFM42W/GX24Q

CFQ26W/G24Q

F25T8

F25T8

F25T8

F32T8

F32T8

F32T8

FT40W/2G11

FT40W/2G11

39

31

24

21

39

20

14

33

17

11

29

14

39

31

24

21

39

20

14

33

17

11

29

14

39

31

24

21

39

20

14

33

17

11

29

14

VEZ-1T32

VEZ-1T32

VEZ-1T42

VEZ-2Q26

VEZ-132

VEZ-2S32

VEZ-3S32

VEZ-132

VEZ-2S32

VEZ-3S32

VEZ-1TTS40

VEZ-2TTS40

WIRE CONNECTOR / # OF COND.

COMBINATION CHART

1- #12 w/ 1 to 3 #14, #16 or #18
2- #12 w/ 1 or 2 #16 or #18
1- #14 w/ 1 to 4 #16 or #18
2- #14 w/ 1 to 3 #16 or #18

For non-standard wiring

applications, refer to Wire

Nut and Connector Size Chart

Cat. No. IPXØ6-1, 120V, For use with

Advance Transformer 120V Mark 10™

Powerline Electronic Ballasts

Lamp

Max. # Ballasts/

Dimmer for Multi-gang

Two

Ganged

CFM26W/GX24Q

CFM32W/GX24Q

CFM42W/GX24Q

CFQ26W/G24Q

F25T8

F25T8

F25T8

F32T8

F32T8

F32T8

FT40W/2G11

FT40W/2G11

19

16

12

10

19

10

7

17

8

6

15

7

16

13

10

9

16

8

6

14

7

5

12

6

More than

2 Gang

13

10

8

7

13

7

5

11

6

4

10

5

Single

Gang

REZ-IT32

REZ-IT32

REZ-IT42

REZ-2Q26

REZ-132

REZ-2S32

REZ-3S32

REZ-132

REZ-2S32

REZ-3S32

REZ-1TTS40

REZ-2TTS40

Advance

Mark 10™
Powerline

Part No.

CFM26W/GX24Q

CFM32W/GX24Q

CFM42W/GX24Q

CFQ26W/24Q

F25T8

F25T8

F25T8

F32T8

F32T8

F32T8

FT40W/2G11

FT40W/2G11

Cat. No. IPX1Ø-1, 120V, For use with

Advance Transformer 120V Mark 10™

Powerline Electronic Ballasts

Lamp

Max. # Ballasts/

Dimmer for Multi-gang

Two

Ganged

32

26

20

17

32

17

11

28

14

9

25

12

26

21

16

14

26

13

9

22

11

8

20

10

More than

2 Gang

22

18

14

12

22

12

8

19

10

7

17

9

Single

Gang

REZ-1T32

REZ-1T32

REZ-1T42

REZ-2Q26

REZ-132

REZ-2S32

REZ-3S32

REZ-132

REZ-2S32

REZ-3S32

REZ-1TTS40

REZ-2TTS40

Advance

Mark 10™
Powerline

Part No.

Cat. No. IPX12-7, 277V, For use with

Advance Transformer 277V MarkX™

Powerline Electronic Ballasts

Lamp

Max. # Ballasts/

Dimmer for Multi-gang

Two

Ganged

More than

2 Gang

Single

Gang

Advance

Mark 10™
Powerline

Part No.

Cat. No. IPXØ6-7, 277V, For use with

Advance Transformer 277V Mark 10™

Powerline Electronic Ballasts

Lamp

Max. # Ballasts/

Dimmer for Multi-gang

Two

Ganged

CFM26W/GX24Q

CFM32W/GX24Q

CFM42W/GX24Q

CFQ26W/G24Q

F25T8

F25T8

F25T8

F32T8

F32T8

F32T8

FT40W/2G11

FT40W/2G11

20

15

12

10

20

10

7

17

8

6

14

7

20

15

12

10

20

10

7

17

8

6

14

7

More than

2 Gang

20

15

12

10

20

10

7

17

8

6

14

7

Single

Gang

VEZ-1T32

VEZ-1T32

VEZ-1T42

VEZ-2Q26

VEZ-132

VEZ-2S32

VEZ-3S32

VEZ-132

VEZ-2S32

VEZ-3S32

VEZ-1TTS40

VEZ-2TTS40

Advance

Mark 10™
Powerline

Part No.

Reviews: