Identifying your wiring application
(most common):
WARNING: If the wiring in the wall box does not resemble any
of these configurations, consult an electrician.
QUIET FAN SPEED CONTROL
Single Pole or 3-Way
Cat. No. 661F – Ceiling Fan 1.5A
120VAC, 60Hz
INSTALLATION INSTRUCTIONS
Step 3
Step 2
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
WARNING:
TO AVOID FIRE, SHOCK, OR DEATH; TURN
OFF POWER at circuit breaker or fuse and test that power is
off before wiring or servicing fixture!
Step 1
Single Pole
1. Line (Hot)
2. Neutral
3. Ground
4. Load
NOTE: For 3-Way applications, note that one of the screw terminals from
the old switch being removed will usually be a different color (Black) or
labeled Common. Tag that wire with electrical tape and identify as the
common (Line or Load) in both the Fan Speed Control wall box and 3-way
switch wall box.
Preparing and connecting wires:
Strip gage
Cut
(if necessary)
5/8"
• Make sure that the ends of the wires from the
wall box are straight
(cut if necessary).
• Remove 5/8" (1.6 cm) of insulation from each
wire in the wall box (shown).
•
For Single-Pole Application, go to Step 4a.
•
For 3-Way Application, go to Step 4b.
Single-Pole Wiring Application:
Step 4a
3-Way
1. Line or Load (See note below)
2. Neutral
3. Ground
4. First Traveler – note color
5. Second Traveler – note color
DI-000-0661F-02A
3
2
4
1
5
3
2
1
4
Cap with
Wire Connector
Green
Ground
Black
Red
Red
Hot (Black)
Neutral (white)
Line
120VAC, 60Hz
Fan Speed Control
NOTE: There is NO derating
necessary for multi-gang
installations of this Fan
Speed Control.
Tools needed to install your Fan Speed Control
Installing your Fan Speed Control
Slotted/Philips Screwdriver Electrical Tape
Ruler
Pliers Pencil
Cutters
Installing Control by itself or with other devices
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to
GREEN control lead.
• Line Hot wall box wire to
BLACK control lead.
• Load wall box wire to
RED control lead.
• Remaining
RED control lead should have a label affixed.
DO NOT REMOVE this label in a single pole application.
NOTE: If the insulating label is not affixed to the second RED lead
use electrical tape or a wire connector to cover.
Proceed to Step 5.
Red
Black
Neutral
Green
Ground
Red
This wire is used in 3-way installations only.
For single pole installations,
do not remove this insulating label.
Insert wires
straight
then twist
clockwise
Electrical Tape
instructions or rating label on the motor to confirm type. Use with any other types of motors or equipment may cause
overheating and/or damage to the motors or equipment.
• Use only one (1) Fan Speed Control per load. The switch(es) will turn ON the fan at the speed level selected at the control.
• To avoid overheating and possible damage to this device and other equipment,
DO NOT install to control a receptacle,
fluorescent lighting, a motor or a transformer-operated appliance other than appropriate ceiling fans.
• If you are unsure about any part of these instructions, consult an electrician.
• Use this device with
copper or copper clad wire only.
WARNINGS:
•
TO AVOID FIRE, SHOCK, OR DEATH: TURN OFF POWER at circuit breaker or fuse and test that power is off
before wiring or servicing fixture!
•
TO AVOID FIRE, SHOCK, OR DEATH: this control is to be used with ceiling fans that are rated 120VAC, total load
1.5 amperes maximum.
• Use and/or install in accordance with appropriate electrical codes and regulations.
CAUTIONS:
•
For use on ceiling paddle fans with split-capacitor or shaded pole motors only. Please refer to manufacturer’s