background image

INSTALLING THE BWBC2 – QUICK START – CONTINUED

3)   Location Settings

 – The BWBC2 has a built-in scheduler that will also allow events to be triggered based on a 

specific time, sunrise or sunset.  In order for the sunrise and sunset calculations to work properly, it is necessary 
to set the Location in the Project node.

a.

   Right-Click on the Project Node and select “Location”

b.

   Type the name of your city or town and click search to find your Lat/Long and click “OK”.

4)  Email Settings

 – The BWBC2 can also send email notifications to recipients based on events or macros.

a.

   Right-Click on the Project Node and select “Email Settings”

b.

   Fill out the fields using the proper email server settings. For a list of common SMTP email server settings go 

to 

http://www.emailaddressmanager.com/tips/mail-settings.html

c.

   Add recipients to the project and Send a test to yourself to verify email server settings.

CONGRATULATIONS!

You now have a BWBC2 configured on the network and ready to program. For more details on programming for 
devices, macros and GUI interfaces, please view our training video series available in the Support Center.

CONTACT

Technical Support:

 1-800-824-3005

Email:

 [email protected]

[email protected]

Web:

 www.leviton.com/automation

INSTALLING THE BWBC2 – QUICK START

The BWBC2 (like the BWBC4) is an IP based controller and does need to be connected to a Local Area Network 
(LAN). The BWBC2 is shipped from the factory in DHCP mode and should be able to obtain an IP address as long 
as there is a DHCP server available on the network. 

NOTE:

 BWBC2 programming and functionality require Project Editor Software version 1.9 or Higher.

1)  Add the BWBC2 controller to a new or existing project.

a.

   Connect the BWBC2 to your LAN via the Ethernet Port and power from the included power adapter.

i.

   During start-up the Red Status LED on the front of the unit will blink in a “Heartbeat” pattern until all 

processes are loaded and running. (This takes about 45 seconds.)

b.

   Start Project Editor Software and open an existing project or create a new one. Right-click on the BWBC2’s 

node of the Project and select “Add Controller from Network”. In the resulting Controller Discovery Window, 
select the IP address for the BWBC2 and select “Add to Project”.

2)   Modify properties for the newly added BWBC2 via right-click on the BC2:BWCBC2 node in the project.

a.

   Network Settings

i.

   Give the BWBC2 a meaningful name for the project.  Perhaps the client’s name or the location.

ii.

   Uncheck the “Use DHCP” checkbox

iii.

   Assign a valid static IP address to the BWBC2

iv.

   Click “Apply Settings to BWBC2” 

b. 

  Time

i.

   Choose the Appropriate Time Zone for the install from the drop down menu.

ii.

   Make sure the current Time and Date from your PC are shown in the two lines below the drop down and 

click the “Set” button to set the BWBC2 time and date.

CONNECTIVITY

Ethernet

10/100 Base-T

USB 2.0

2 Ports - future expansion

DEVICE CONTROL

IR Ports

4 (routable, attenuable)

RS232

2 (1 DB9, 1 terminal strip)

Relays

2 (SPDT)

Signal Sense

2 (analog or digital)

Network

Yes

DIMENSIONS

H x W x D

1.68 in. x 7.56 in. x .87 in.

H x W x D (packaging)

4 in. x 12 in. x 9 in.

MOUNTING

Shelf

Yes

Rack

Yes (rack ears sold separately)

POWER

External

12 VDC - 0.5 A (adapter included)

SPECIFICATIONS

© 2015 Leviton Mfg. Co., Inc.

DI-000-BWBC2-00A

WEB 

VERSION

Reviews: