 Wiring your Dimmer –

Connect wires per WIRING DIAGRAM as follows: Twist strands
of each lead tightly together and, with circuit conductors, push
firmly into appropriate wire connector. Screw connectors on
clockwise making sure no bare conductors show below the wire
connectors. Secure each connector with electrical tape.
For all multi-location applications, the dimmer must be installed
in a wall box that has a Load connection. The remote must be
installed in a wall box with a Line Hot connection and a Neutral
connection.
If you are unsure about any part of these instructions, consult a
qualified electrician.
NOTE: Maximum wire length from dimmer to all installed
remotes  cannot exceed 300 ft.

Single Pole (One location) or 3-Way (Multi-location)

Fluorescent Dimmer (Lighted)

Cat. No. ACHØ8

8A-120VAC, 60Hz

For use with Hi-lume

®

 or Eco-10™ (EcoSeries) dimmable ballasts

INSTALLATION INSTRUCTIONS

DI-000-ACH08-00A-X0

 Tools needed to install your Dimmer:

Slotted/Phillips Screwdriver

Electrical Tape

Pliers

Pencil

Cutters

Ruler

 Installing Dimmer by itself or with other devices:

If installing Dimmer in a single device application, proceed with the
INSTALLING YOUR DIMMER section. If installing Dimmer in a multi-
device application, proceed as follows:

MULTI-DEVICE APPLICATION

In multi-dimmer installations, there is no derating necessary.
Breaking off fins is not required on this device. Refer to the chart for
maximum load per dimmer.

  Single-Pole Wiring Application:

WARNINGS AND CAUTIONS:

To be installed and/or used in accordance with appropriate electrical codes and regulations.

If you are unsure about any part of these instructions, consult a qualified electrician.

To avoid overheating and possible damage to this device and other equipment, use only with the appropriate Lutron 120V Hi-lume

®

 or Eco-10™ (EcoSeries)

electronic ballasts for controlling the specific fluorescent lamps.

Acenti™ dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Acenti™ remotes for multi-location dimming.

Use only one (1) dimmer in a multi-location circuit with up to 9 coordinating remotes without LEDs or up to 4 matching remotes with LEDs. The remote(s) will
turn the light on at the brightness level selected at the dimmer.

Only use lamps listed on ballast label. Compact Fluorescent lamps must have four pins for dimming.

Lamps must be burned in at full intensity for 100 hours prior to dimming for proper dimming performance.

WARNINGS AND CAUTIONS:

For new installations, wire a test switch before installing dimmer.

Total minimum load must exceed 40W.

Dimmer may feel warm to the touch during normal operation.

Recommended minimum wall box depth is 2-1/2".

Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.

Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.

Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.

  3-Way Wiring with Coordinating Remote (no LEDs)
  Application:

For non-standard wiring applications, refer

to Wire Nut and Conductor Size Chart

Insulating label:
This wire is used in 3-way installations only.
For single pole installations, do not remove
this insulating label.

Black

White

Green

Orange

Red

Yellow/Red

Dimmer

BL

WH

YL/RD RD

Black

White

Green

Orange

Red

Yellow/Red

Terminal

Screw marked 

Yellow/Red 

(YL/RD)

Terminal Screw marked 

White (WH)

Coordinating Remote

The maximum current rating is 8A, which can be measured from the
incoming Hot (Black) on the dimmer. Refer to the ballast label to
determine the total load on the dimmer circuit. The total load is
calculated by adding all of the ballast input currents for all ballasts on
dimmer.

Preparing and connecting wires:

Pull off pre-cut insulation from dimmer leads. Make sure that
the ends of the wires from the wall box are straight (cut if
necessary)
. Remove insulation from each wire in the wall
box as shown.

Step 1

WARNING:

 TO AVOID FIRE, SHOCK, OR DEATH;

TURN OFF POWER at circuit breaker or fuse and test
that power is off before wiring!

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

Step 2

Cut

(if necessary)

Strip Gage
(measure bare
wire here)

1 - #12 w/ 1 to 3 #14, #16 or #18
2 - #12 w/ 1 or 2 #16 or #18
1 - #14 w/ 1 to 4 #16 or #18
2 - #14 w/ 1 to 3 #16 or #18

WIRE NUT / # OF COND.

COMBINATION CHART

INSTALLING YOUR DIMMER

NOTE: Use check boxes       when Steps are completed.

5/8"

(1.6 cm)

Alignment Plate

Held By Tape

TOP

Electrical
Tape

Alignment Plate

Held By Wires

TOP

Step 4

C

B

ACHØ8

     8A

              8A

             8A

              More than

Cat. No.

    Single

        Two Devices          2 Devices

MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE

CAUTION:

Before installing your dimmer, check new installation wiring for any
shorts in the circuit.

Turn OFF Power at circuit breaker or fuse.

Using a standard switch, connect appropriate wires to Hot circuit
and ballast (refer to diagram).

Turn ON Power. If lights do not turn ON, there is an open in the
circuit.

If required, Turn OFF Power and correct wiring. Verify circuit
again. Warranty of dimmer will be voided if dimmer is turned
ON in a shorted circuit.

Hot 

Neutral

Black

White

Ballast

Switch

Orange

Line 

120VAC, 60Hz

Installing your Alignment Plate:

Important Notice for Installer

To achieve proper aesthetic installation of the Acenti products, the
wall surface surrounding the wall box opening must be fairly flat and
free of irregularities. The wall box must be level and recessed or
flush to the wall surface. The Acenti installation system allows for
adjustments that will correct minor flaws that may be present in the
installation area.
This device must be installed with the Acenti™ Alignment Plate. The
Alignment Plate is packaged with the Acenti™ Wallplate, which is
sold separately from this device.
The Alignment Plate will function properly only if it is mounted to a
flat wall surface as described above.
Leviton recommends to temporarily position the Alignment
Plate prior to wiring the device. If the wall box wires
extend at least 6 inches out of the wall box, it is also
possible to install the Alignment Plate after the device has
been wired (refer to Wallplate instruction sheet).

The Alignment Plate must be installed with the tab towards the
bottom.

Leviton recommends the following 3 methods to temporarily hold
the Alignment Plate – use of device mounting screw, use of wall
box wires, or use of electrical tape (refer to the following
figures)
:

Step 3

Alignment Plate Held

By Mounting Screw

TOP

Mounting
Screw

Alignment
Plate

A

1 For Single-Pole Application, go to Step 4a.

2 For 3-Way Coordinating Remote (no LEDs) Application, go to

Step 4b.

3 For 4-Way Coordinating Remote (no LEDs) Application, go to

Step 4c.

4 For 3-Way Matching Remote (with LEDs) Application, go

to Step 4d.

5 For 3-Way Matching Remote (with LEDs) Application, go to

Step 4e.

Hot (Black)

Neutral (White)

LOAD

120V Hi-lume

®

or 

Eco-10™ (EcoSeries)

Ballast

Dimmer

Coordinating Remote 

(no LEDs)

Black

Orange

Orange

Black

White

White

WH

Red

Green 

Ground 

Line 

120VAC, 60Hz

Yellow/ 
Red

YL/RD

Green 

Ground 

BL

RD

(not used)

(not used)

Hot (Black)

Neutral (White)

LOAD

120V Hi-lume

®

or 

Eco-10™ (EcoSeries)

Ballast

Dimmer

Black

Orange

Orange

Black

White

White

Red

Green 
Ground 

Line 

120VAC, 60Hz

Yellow/ 
Red

Insulating

Label

  Single-Pole Wiring Application (cont’d):

A

B