Leviton 804CP Installation & Operation Manual Download Page 9

Page 9

Operation

Slide controls:

Moving a slide control will cause an immediate takecontrol of all dimmers assigned to that 

zone. The lighting levels will fade up or down quickly to match the slide control level, and the 

LED of the zone will illuminate indicating that the slider has full control (This feature may be 

modified through computer software wheras the MANUAL button must first be pressed to gain 

control).

The LED of the zone will go out when either the PRESET or ALL OFF button is pressed, or if 

another panel gains control of the dimmer channel assigned (A control console will not affect 

the LEDs).

Default dimmer assignment are : Zone 1-4 (1-8) = Dimmer Channel 1-4 (1-8).

MANUAL button:

When pressed, this button will cause all dimmer channels assigned to all zones of this panel 

to fade to the current settings of the slide controls. All zone LEDs will come on and the slide 

controls will have full control.

PRESET button:

This button will cause all dimmer channels assigned to all zones of this panel to fade to the 

zone setting previously programmed (Default is all full on). All zone LEDs will go out.

ALL OFF button:

This button will cause all dimmer channels assigned to all zones of this panel to fade to the 

zone setting previously programmed (Default is all full off). All zone LEDs will go out.

To restore control from a console:

Simply perform a change in the channel level from the console. The lighting channel will 

then fade back to the new console level at the factory default fade rate. Once the console 

level matches or is moved past the lighting level, full console control will be resumed for that 

channel.

LUMA-NET

LUMA-NET

MEMORY LIGHTING CONTROLLER

PRESET

MANUAL

OFF

PRESET

MANUAL

OFF

MEMORY LIGHTING CONTROLLER

CONTROL ACTIVE

CONTROL ACTIVE

804  CP

808  CP

PWR  

BUSY

PWR  

BUSY

WEB 

VERSION

Summary of Contents for 804CP

Page 1: ...804CP 808CP Remote Control Panel Installation Operation Guide WEB VERSION ...

Page 2: ...Page 2 WEB VERSION ...

Page 3: ...INTRODUCTION 4 IMPORTANT 4 WIRING 4 PROGRAMMING 6 OPERATION 9 Table of Contents WEB VERSION ...

Page 4: ...nd control systems explicitly designed for interfacing with it Communication between the panels and the dimming system is via a 4 wire interface Three wires carry the RS 422 485 bi directional data A fourth wire carries the DC voltage necessary for powering the unit Wiring cable between the panels and the dimming system is class 2 and should be at least 22 AWG 4 conductor shielded twisted pairs BE...

Page 5: ...essful reconfiguration of the network If the BUSY LED flashes slowly this indicates a duplicate ID number or wiring problem Program the ID number if not already and observe the BUSY LED Note the busy LED also flashes quickly when the program jumper is removed Now test the dimmer function by operating the panel If the dimmer responds then mount the panel and procede to the next panel in the system and...

Page 6: ...program the PRESET and ALL OFF buttons easily without additional equipment Other features such as dimmer channel assignment and fade time require a computer and software Details on programming other features are supplied with the Luma Net Software Package Optionally the unit may be ordered preprogrammed from the factory TERMINATION JUMPER PROGRAM JUMPER PROGRAM JUMPER ID NUMBER DIP SWITCH ID NUMBE...

Page 7: ...network all panels and devices attached except dimmers must have a unique network ID number If two panels have the same network ID number the entire network will stop functioning Panels need not be in program mode to change network ID number since a dipwitch is used To set Network ID number 1 Locate dipswitch on rear of unit as illustrated below 2 Set the switches as per the chart on the following...

Page 8: ...011100 60 00111100 61 10111100 62 01111100 63 11111100 64 00000010 65 10000010 66 01000010 67 11000010 68 00100010 69 10100010 70 01100010 71 11100010 72 00010010 73 10010010 74 01010010 75 11010010 76 00110010 77 10110010 78 01110010 79 11110010 80 00001010 81 10001010 82 01001010 83 11001010 84 00101010 85 10101010 86 01101010 87 11101010 88 00011010 89 10011010 90 01011010 91 11011010 92 001110...

Page 9: ...rrent settings of the slide controls All zone LEDs will come on and the slide controls will have full control PRESET button This button will cause all dimmer channels assigned to all zones of this panel to fade to the zone setting previously programmed Default is all full on All zone LEDs will go out ALL OFF button This button will cause all dimmer channels assigned to all zones of this panel to f...

Page 10: ...Page 10 NOTES WEB VERSION ...

Page 11: ...Page 11 NOTES WEB VERSION ...

Page 12: ... normal operating conditions or not in accordance with any labels or instructions There are no other or implied warranties of any kind including merchantability and fitness for a particular purpose but if any implied warranty is required by the applicable jurisdiction the duration of any such implied warranty including merchantability and fitness for a particular purpose is limited to two years Levi...