background image

Working with the application for Mac OS users

Installing software

Browse to the 

mac

 folder on the installation CD and copy 

MicroCapture

 file 

to the desktop. 

Operating the microscope

Use a USB cable to connect the microscope to your computer. Run the MicroCapture 
application by double-clicking its icon.

Observing specimens

A magnified image of the observed specimen may be seen in the main window of the 
application.

Image resolution

From the 

Options

 menu, select 

Preview Size

 to set the image resolution. Keep in mind 

that the preview window cannot be resized (standard resolution is 640x480). The image 
resolution is shown in the bottom left corner of the preview window.

Date and time

From the 

Options

 menu, select 

Date/Time

 to display or hide the date and time 

of capture during preview.

Capturing an image

Click the corresponding icon on the toolbar or select 

Photo

 from the 

Capture

 menu 

to capture an image. An image thumbnail will appear on the right side of the main 
window.

Recording a video

Click the corresponding icon on the toolbar or select 

Video

 from the 

Capture

 menu 

to start recording a video.

Note

:

 during recording, the camcorder icon on the toolbar will turn red. Click the icon 

again to stop recording.

Editing images and videos

Image and video thumbnails are displayed on the right side of the main window of the 
application. Double-click an image thumbnail to open it in a separate preview window. 
Editing images with MicroCapture application is similar to working with other 
applications in Mac OS. 

Care and maintenance

Never, under any circumstances, look directly at the Sun, another bright source of light or at a 
laser through this device, as this may cause PERMANENT RETINAL DAMAGE and may lead to 
BLINDNESS

.

 White LEDs are very bright; do not look at them as this may cause permanent 

damage to your vision. Take necessary precautions when using the device with children or 
others who have not read or who do not fully understand these instructions. After unpacking 
your microscope and before using it for the first time check for integrity and durability of 
every component and connection. Do not try to disassemble the device on your own for any 
reason. For repairs and cleaning of any kind, please contact your local specialized service 
center. Protect the device from sudden impact and excessive mechanical force. Do not apply 
excessive pressure when adjusting focus. Do not overtighten the locking screws. Do not touch 
the optical surfaces with your fingers. To clean the device exterior, use only special cleaning 
wipes and special optics cleaning tools from Levenhuk. Abrasive particles, such as sand, 
should not be wiped off lenses, but instead blown off or brushed away with a soft brush. Do 
not use the device for lengthy periods of time, or leave it unattended in direct sunlight. Keep 
the device away from water and high humidity. Be careful during your observations, always 
replace the dust cover after you are finished with observations to protect the device from dust 
and stains. If you are not using your microscope for extended periods of time, store the 
objective lenses and eyepieces separately from the microscope. Store the device in a dry, cool 
place away from hazardous acids and other chemicals, away from heaters, open fire and 
other sources of high temperatures. To avoid data loss or equipment damage, always close 
the application first, and then disconnect the microscope from your PC. Wait until the 
illumination goes off completely, and disconnect the microscope. Seek medical advice 
immediately if a small part or a battery is swallowed.

Battery safety instructions

Always purchase the correct size and grade of battery most suitable for the intended use. 
Always replace the whole set of batteries at one time; taking care not to mix old and new 
ones, or batteries of different types. Clean the battery contacts and also those of the device 
prior to battery installation. Make sure the batteries are installed correctly with regard to 
polarity (+ and -). Remove batteries from equipment that is not to be used for an extended 
period of time. Remove used batteries promptly. Never attempt to recharge primary batteries 
as this may cause leakage, fire, or explosion. Never short-circuit batteries as this may lead to 
high temperatures, leakage, or explosion. Never heat batteries in order to revive them. 
Remember to switch off devices after use. Keep batteries out of the reach of children, to avoid 
risk of ingestion, suffocation, or poisoning.

4

Summary of Contents for DTX 30

Page 1: ...Levenhuk DTX 30 DTX 50 Digital Microscope User Manual N vod k pou it Bedienungsanleitung Gu a del usuario Instrukcja obs ugi RU PL ES DE Z EN 2 MEGA PIXELS 230x 400x 1 3MEGA PIXELS...

Page 2: ...ion The installation CD contains a copy of this User Guide which you can read by clicking the corresponding entry in the Main Menu LED light brightness control wheel Shutter button Focus wheel Calibra...

Page 3: ...ing the microscope you will be able to measure various parameters of observed specimens All the buttons on the toolbar of the preview window are described below Line Press and hold the left mouse butt...

Page 4: ...emble the device on your own for any reason For repairs and cleaning of any kind please contact your local specialized service center Protect the device from sudden impact and excessive mechanical for...

Page 5: ...eries rechargeable and non rechargeable electrical consumables etc For further details please visit our web site www levenhuk com warranty System requirements Operating system Windows XP SP2 Vista 7 8...

Page 6: ...lavn nab dce Rozli en obrazu V nab dce Options Mo nosti zvolte mo nost Preview Size Velikost n hledu a nastavte rozli en obrazu Ot en sn mku V nab dce Options Mo nosti vyberte mo nost Rotate Oto it a...

Page 7: ...a po i te sn mek Pod vejte se na kalibra n stupnici na t le mikroskopu a zaznamenejte si aktu ln zv t en Dvojit m kliknut m na n hled obr zku jej otev ete v samostatn m okn Do p slu n ho pole v prav...

Page 8: ...opu a p ed jeho prvn m pou it m zkontrolujte neporu enost jednotliv ch komponent a spoj Nedot kejte se sv mi prsty povrch optiky K vy i t n o ek m ete pou t m kk ubrousek nebo istic ut rku navlh en v...

Page 9: ...nformace nav tivte na e webov str nky www levenhuk cz zaruka Technick daje Spole nost Levenhuk si vyhrazuje pr vo prov d t bez p edchoz ho upozorn n pravy jak hokoliv v robku p padn zastavit jeho v ro...

Page 10: ...ierungslineal Bildaufl sung W hlen Sie zum Einstellen der Bildaufl sung im Men Optionen den Eintrag Voransichtsgr e Drehen des Bilds W hlen Sie im Men Optionen den Eintrag Drehen Sie k nnen die erstel...

Page 11: ...eichert werden Beim Speichern von Bildern im jpeg Format k nnen Sie auf Erweitert klicken und weitere Optionen anzeigen und einstellen L schen von Bildern Klicken Sie zum L schen eines Bilds mit recht...

Page 12: ...tierungsschrauben nicht zu fest an Ber hren Sie die optischen Fl chen nicht mit den Fingern Verwenden Sie zur u erlichen Reinigung des Teleskops ausschlie lich die speziellen Reinigungst cher und das...

Page 13: ...n Sie bitte unserer Website http de levenhuk com garantie Technische Daten Bildsensor Vergr erung M gliche Bildaufl sungen DTX 50 M gliche Bildaufl sungen DTX 30 M gliche Videoaufl sungen DTX 50 M gli...

Page 14: ...talaci n ser necesario reiniciar el sistema 14 Levenhuk DTX 30 DTX 50 Rueda de control de la luz LED Bot n disparador Rueda de enfoque Regla de calibrado Resoluci n de la imagen En el men Opciones sel...

Page 15: ...lir de la aplicaci n Para salir de la aplicaci n elija Salir en el men Archivo Consejo Tambi n puede cambiar sus preferencias y ajustes editando el archivo Settings ini que se encuentra en el director...

Page 16: ...n de la imagen Recuerde que la ventana de la vista preliminar no se puede cambiar de tama o la resoluci n est ndar es de 640x480 La resoluci n de la imagen se muestra en la esquina inferior izquierda...

Page 17: ...odo largo de tiempo Retire lo antes posible las pilas agotadas No intente nunca recargar pilas primarias pilas de un solo uso ya que podr a provocar fugas fuego una o explosi n No cortocircuite nunca...

Page 18: ...instalacyjna zawiera kopi niniejszej instrukcji z kt rej tre ci mo na zapozna si klikaj c odpowiadaj c pozycj w menu g wnym 18 Levenhuk DTX 30 DTX 50 Pier cie do regulacji jasno ci pod wietlenia Przy...

Page 19: ...menu Obr bka nagra wideo Kliknij prawym przyciskiem myszy miniatur wybranego filmu wideo aby obejrze skopiowa lub usun film wybieraj c odpowiednie opcje z rozwijanego menu Zamykanie aplikacji Aby wyj...

Page 20: ...h aplikacji w systemie Mac OS 20 Instrukcje dotycz ce bezpiecznego obchodzenia si z bateriami Nale y u ywa baterii odpowiedniego typu i w odpowiednim rozmiarze Nale y wymienia wszystkie baterie jednoc...

Page 21: ...zyszcz cej lub ciereczki nas czonej alkoholem Polecamy stosowanie specjalnych rodk w do czyszczenia uk adu optycznego firmy Levenhuk Nie czy ci uk adu optycznego za pomoc rodk w r cych lub zawieraj cy...

Page 22: ...l Microscope Driver MicroCapture software 22 Levenhuk DTX 30 DTX 50 Preview Size Options Rotate Options 90 Date Time Options Skin Options Language Options 1 2 3 Fullscreen mode Options Preferences Opt...

Page 23: ...23 Video Capture Stop capturing Capture 640x480 Save jpeg bmp jpeg Advanced Delete Copy Exit File Settings ini...

Page 24: ...Levenhuk DTX MicroCapture USB MicroCapture MicroCapture Preview Size Options 640 480 Date Time Options Photo Capture Video Capture Mac OS Levenhuk 5 50 24 1 20 400 Levenhuk DTX 50 230 Levenhuk DTX 30...

Page 25: ...30 1600x1200 1280x1024 1280x960 1024x768 800x600 640x480 352x288 320x240 160x120 2560 x2048 5M 2000x1600 1600x1280 2M 1280x1024 1024x960 1024x768 800x600 640x480 352x288 320x240 160x120 1600x1200 1280...

Page 26: ...ta zakupu Stamp Raz tko Stempel Sello Piecz Signature Podpis Unterschrift Firma Podpis levenhuk com Levenhuk Inc 924 D East 124th Ave Tampa FL 33612 USA Levenhuk is a registered trademark of Levenhuk...

Page 27: ......

Page 28: ...uk cleaning accessories Levenhuk Cleaning Pen LP10 Removes dust with a brush The soft tip is treated with a special cleaning fluid that removes greasy stains Does not damage optical coatings of the le...

Reviews: