LevelOne MDU-2400FXC Installation Manual Download Page 3

 

-3- 

Installation 

Please be sure the power of the system is down during the installation. Insert one or two modules 

into the slots on the front panel of the switch (be sure the module is aligned within the guide-rails 

and that the two fasteners on the front side of the module are tightened), as shown in the 

following figure. 

GSW-1600TXM with MDU-2400FXC 

 

GSW-1600TXM with MDU-2800T X 

 

GSW-1600TXM with MDU-2100SX 

 

Note: For 

MDU-2100SX 

1000SX Gigabit Switch Module. The transmitter of the Fiber Optic 

Transceiver is on the left -hand side (the one close to the Power LED) while the receiver is on the 

right-hand side (the one close to the Link LED). 

 

 

 

17

18

1 9 2 0 2 1

22

23

24

100/10M

Full/Col

L i n k / A c t

100/10M

Full/Col

L i n k / A c t

S y s t e m

1

Module1

1

M o d u l e 2

GSW-1600TXM 16 Port 10/100Mbps SNMP Switch

17

18

1 9 2 0 2 1

22

23

24

100/10M

Full/Col

L i n k / A c t

100/10M

Full/Col

L i n k / A c t

S y s t e m

1

Module1

1

M o d u l e 2

GSW-1600TXM 16 Port 10/100Mbps SNMP Switch

17

18

1 9 2 0 2 1

22

23

24

100/10M

Full/Col

L i n k / A c t

100/10M

Full/Col

L i n k / A c t

S y s t e m

1

Module1

1

M o d u l e 2

GSW-1600TXM 16 Port 10/100Mbps SNMP Switch

Summary of Contents for MDU-2400FXC

Page 1: ...1 MDU 2400FXC 4 Port 100Mbps SC Fiber Switch Module MDU 2800TX 8 Port 10 100Mbps Fast Ethernet Switch Module MDU 2100SX 1000SX Gigabit Switch Module Installation Guide...

Page 2: ...lable Ethernet Switch The user can choose to slide in up to two of the modules to increase 10 100Mbps port density This users guide describes the installation steps for the 8 Port 100Base TX module Al...

Page 3: ...the FiberOptic Transceiver is on the left hand side the one close to the Power LED while the receiver is on the right hand side the one close to the Link LED 1 7 1 8 1 9 2 0 2 1 2 2 2 3 2 4 100 10M F...

Page 4: ...ED columns 17 to 20 are used as indicators for the module When the MODULE 2 slot is used LED columns 25 to 28 are the indicators There are three LEDs for each port Their definitions are described as f...

Page 5: ...ns 17 to 24 are used as indicators for this module When the MODULE 2 slot is used LED columns 25 to 32 are the indicators There are three LEDs for each port Their definitions that described as follows...

Page 6: ...hen the MODULE 2 slot is used the port becomes Port 25 of the switch There are three LEDs for the 1000Mbps port Their definitions are described as follows Power LED Off No power Solid Green System is...

Page 7: ...Switch Module Standard Interface Environment Dimension EMI IEEE802 3u 100Base TX RJ 45 connector Temperature Operating 0 C to 40 C Storage 20 C to 70 C Humidity Operating 10 RH to 90 RH Storage 5 RH t...

Reviews: